AMC2100 Series0 pages
ALIAMAG
®
Converter For Electromagnetic Flowmeter
Model AMC2100 Series
GENERAL
ALIAMAG The Aliamag AMC2100 series converter is a microprocessor
based intelligent transmitter that can be paired with any of the Alia AMF
series sensors. The unit features multiple display parameters including
flow rate, flow total, diagnostics, programming and troubleshooting.
FEATURES
Three line LCD display Flow Rate / Totalizer
Accuracy of +/-0.4% value of reading
Bi-directional flow measurement, current and pulse output
Large digital display
Records up to 99 power on/off time
MODBUS/HART communication
STANDARD SPECIFICATION
Excitation
: DC pulsed
Display
: 3 lines LCD with illumination
Line 1 : 11 digit totalizer for forward flow
Keypad
: 3 external keys for programming
and display control
Low Flow Cutoff
: 0 to 9.9 %
11 digit totalizer for reverse flow
Data Logger Function
: 99 times flowrate records for power on/off
11 digit totalizer for difference
Record Data
: Date/Time when Power on/off
Line 2 : 5 digit flowrate / velocity / % / mA / HZ
: Flow rate when Power on/off
Line 3 : Parameter / Query / Clr tot / Query LOG
: Totalizer when Power on/off
Alarm, Guidance
Unit : M3/H, L/H, Kg/H, T/H, L/min, M3/min, GPH
GPM, ML/H, ML/m, ML/sec
Measuring Range
Damping
: 0 to 99 Seconds
Density Setting
: 0.1 to 9.99 g/cm3
Self Diagnosis
: The following error message are
: Min. 0 to 0.15 m/s
displayed if failure occurs
: Max. 0 to 15 m/s
- Coil failure
: +/-0.4% of reading (Velocity ≥ 0.5 m/s)
- Power failure
: +/-0.002 m/s (Velocity < 0.5 m/s)
- Overranged output
Repeatability
: +/-0.1% of reading
- Internal error
Current Output
: 4-20 mA (Isolated)
- Overflow
Accuracy
Load : Max. 600 Ω
Pulse Output
: Open collector
Rating : 3 to 30 VDC, 20 mA Max.
Pulse Rate
- Empty pipe
Cable Entry
: Standard :PG11 Option:1/2"NPTF
Protection Class
: IP 65
: 1)Scale pulse (Pusle/M3, Pulse/L, Other)
Ambient Temperature : -25 to +65 °C
: 2)Frequency: 0-5000 Hz
Material
: Aluminum Alloy
Pulse Width
: 50% of band width
Power Supply
: 90-260 VAC, 50/60 Hz
Alarm
: High/Low with open collector output
Rating : 3 to 30 VDC, 20 mA Max.
Communication
: 24VDC +/-10% (Option)
Power Consumption
: 3-17 W (Dependent on sensor size)
Weight
: 1.4 Kg
: HART signal (Compatible)
Data Storage
: RS 485 (MODBUS Protocol)
Mounting
: Wall mounting
: Operation parameters and totalizer
: Bracket on 2" pipe
figures are stored by EEPROM for more
than 10 years
ALIA GROUP INC.
113 Barksdale Professional Center, Newark, DE 19711, USA
TEL : + 1 - 302 - 213 - 0106
FAX : + 1 - 302 - 213 - 0107
URL : www.alia-inc.com
E-mail : alia@alia-inc.com
AMC2100V1.1.9.A4.en