Model V534 Canners Gauge0 pages
SAG - 19
Product Data
SPECIAL APPLICATION GAUGES
Model V534 Canners Gauge
DESCRIPTION
SPECIFICATIONS
U.S. Gauge V534 Canners Gauge is used for testing
vacuum of packaged products such as canned food or
drink. This gauge is easy to use for destructive sampling
tests. Force the stainless steel needle through the top of
the container while you read the gauge. The rubber gasket prevents air from entering the container during the
test. The 1" graduations in Hg are easy to read within the
2" diameter case. Stainless steel needle can be cleaned
for multiple uses, but is non-removable. Private labeling
is available for OEM applications.
SIZES: 2"
RANGES: Vacuum, 0-30" Hg
ACCURACY: 3-2-3%
BOURDON TUBE: Beryllium copper
WINDOW: Twist-on polycarbonate
MOVEMENT: Brass
DIAL: Galvalume, white background with black graduations
POINTER: Galvalume, black
CASE: Brass, chrome-plated
CONNECTION: Stainless steel piercing needle
Model V534
W SQUARE
V534 Spec Number Selection Chart and Dimensions
Spec No.
050462A
Model
Unit
V534
inches
mm
Dial Size
2"
Range
A
B
C
E
G
W
0-30" Hg VAC
2.26
57.4
1.95
49.5
1.13
28.7
0.43
10.9
2.05
52.1
0.55
14.0
On-line order fax: +1 215-323-9450 or e-mail: usg.sales@ametek.com
Sales/Technical Support: +1 215-293-4100 | 205 Keith Valley Road | Horsham PA 19044 U.S.A.
© 2013, by AMETEK, Inc. All rights reserved.tt
Printed in the U.S.A.tt
PDF513 (160174)
Specifications are subject to change without notice. Visit our Web site for the most up-to-date information.