Thermal Heads - Medium Powers to 300W0 pages
For latest updates please visit our website: www.ophir-spiricon.com
41
9 August 2009
30(150)A / 30(150)A-LP1
CW & Pulsed Measurements 50mW - 150W 20mJ - 300J
Recommended Use: Short term measurement to 150W
Broadband absorber: General use
LP1 absorber: High energy, long pulses
Special Features: Compact, convection cooled
Absorber:
Broadband: 0.19 - 20ìm, LP1: 0.25-2.2ìm
Aperture:
Ø17.5mm
Digital Power Scales:
150W / 30W for BB, 150W/30W/3W for LPI
Maximum Power:
150W for 50s, 100W for 90s 30W continuous
Maximum Average Power Density:
BB: 20KW/cm2, LP1: 35KW/cm2
Power Noise Level:
3mW
Power Accuracy:
±3%a
Maximum Energy Density J/cm2:
<100ns
1ìs
0.5ms
2ms
10ms
Broadband LP1
0.3 0.05
0.5 0.3
5 20
10 50
30 250
Response Time with Display (0-95%):
1.2s
Linearity with Power:
± 1%
Energy Scales:
LP1: 300J/30J/3J BB: 100J/30J/3J
Energy Threshold:
20mJ
Cooling:
Convection
Note a: LP1 heads have relatively large spectral variation in absorption and have a calibrated spectral curve at all wavelengths in their spectral range. When used with the Nova II (software v 1.59 and above) or USBI (V 1.17 or above) supporting this feature, accuracy is ±3% for any wavelength from 250 to 2200nm. When used with displays not supporting this feature, accuracy will be ±3% for wavelengths 532nm, 755nm, 1064nm and 2100nm and ±6% for other wavelengths in the spectral range 400 – 1100nm.
30(150)A
30(150)A-HE / HE1
CW & Pulsed Measurements 50mW - 150W 50mJ - 200J
Recommended Use: High energy and average power pulsed lasers
HE: YAG and harmonics, Holmium, Erbium
HE1: Ruby
Special Features: High damage threshold for short pulses, high average power
Absorber:
HE: 0.19 - 0.625ìm, 1.064ìm, 2.1ìm, 2.94ìm
HE1: 0.19 - 0.76ìm, 2.9ìm
Aperture:
Ø17mm
Digital Power Scales:
150W / 30W / 3W
Maximum Power:
150W for 50s, 100W for 90s 30W continuous
Maximum Average Power Density:
500W/cm2
Power Noise Level:
3mW
Power Accuracy:
±3%a
Maximum Energy Density J/cm2 a:
<100ns
0.5ms
2ms
Single shot 10-50Hz
5 2
100 25
150 40
Response Time with Display (0-95%):
3.8s typ
Linearity with Power:
±1.5%
Energy Scales:
200J / 30J / 3J
Energy Threshold:
50mJ
Cooling:
Convection
Note a: For shorter wavelengths, derate maximum energy density to values shown:
Wavelength Derate to value
355nm 50%
266nm 50%
193nm 10%
Ordering Information
Item
Description
Ophir P/N
30(150)A-V1
Power/energy meter 30W continuous, 150W intermittent
7Z02608
30(150)A-LP1-V1
As above with high damage threshold LP1 coating
7Z02657S
30(150)A-HE
30 / 150 Watt power/energy meter for wavelengths 0.19-2.94ìm. Energy calibrated for 0.19-0.6ìm and 2.9ìm
7Z02380
30(150)A-HE1
30 / 150 Watt power/energy meter for wavelengths 0.19-0.76ìm. Energy calibrated for 0.694ìm (Ruby)
7Z02382
Quasar: Some of the above heads are available with integral Quasar Bluetooth module for wireless transmission direct to PC. .
Thermal Heads - Medium Powers to 300W
30(150)A-HE/HE1