SP3100/EX0 pages

نسخه متنی
"

Embracing Challenge

Gas Sample Probe Series SP®
Version SP3100V and SP3100 for sampling from
zones with explosive gas

SP3100V/RS/HEX4-135 resp. 180

Special Features
Approval according to ATEX for sam-

pling from Ex-zone 0, 1 and 2

Approval according to ATEX for mount-

ing in Ex-zone 1, 2 or 21, 22

Optimum operational reliability
Universal applicability
Adaption to nearly all process condi-

tions due to its compact and modular
design

Easy mounting and maintanancet
Small volume, fast response time

Application
The M&C sample probes version SP3100V and
SP3100 are used for continuous ­ xtraction of
e
explosive gases (Ex-zone 0, 1 and 2) from dust
loaden, high temperature and/or humid processes. The probes can be mounted in Ex-zone
1, 2, 21 and 22. Both versions differentiate only
in the sealing material of the filter housing.
Version SP3100V has got a sealing out of FPM
for types which are heated up to max.185°C
and version SP3100 has got a sealing out of
graphite for all versions heated up to more
than 185 °C.

Description
The sample probes are designed for easy
installation, reliable operation and troublefree maintenance. They are versatile in application and depending on the task to be performed, various pre-filters series V12 or V20
with integrated volume displacer, optional
with extension tubes (see page 4 and data
sheet 2-1.1.0.8), not included in the scale
of delivery, can be simply screwed into the
mounting flange of the basic probe. For error
control the sample gas flow rate has to be
monitored externally.
This M&C stainless steel or ceramic filter element with a large surface and high capacity
is located in the external housing. The design
offers little or no stagnant space outside
the process. The probe housing is covered
with a protection shield which is part of the
Ex-approval.
The probes are designed in such a way that
changing the filter element is possible without the use of tools. In this operation, neither
the sample probe tube nor the sample line
need to be removed, thus avoiding contamination of the clean gas path and maintaining
the ­ntegrity of the system.
i

The temperature control of the M&C-probes
version SP3100(V) can be done by three different heater types.
The first possibility is a self-regulating heater
version HEX4-135 or HEX4-180 (see data sheet
2-3.2) for Ex-zone 1 and 21, for gas sampling
from zone 0, 1 or 2. In dependence on the
ambient temperature and the heater type,
the min. temperature in the probe is 90°C
resp. 120°C, the max. temperature is 120°C
resp. 160°C.
The second possibility is a controlled heating
version HEX1-3 for Ex-zone 1, adjustable up
to 180 °C and for sampling from Ex-zone 1 or
2. The controller has to be mounted outside
the Ex-zone.
The third possibility is a controlled heating
version HEX1-1 for Ex-zone 1, adjustable up
to 180 °C and for sampling from Ex-zone 1 or
2. The controller can be mounted inside the
Ex-zone.
For back-purging the M&C pre-filter, the
option RS is available with mounted buffer
vessel triggered by an explosion-proof solenoid valve. With the mounted option for
back-purging type RS, gas can be sampled
from zone 1 and 2. The back-purge pressure
has to be monitored externally and has to be
min. 1 bar higher than the process pressure.
For the pressure control while back-purging,
a corresponding special valve is mounted
in the sample gas outlet. Thus an additional
solenoid valve to shut off the sample gas
outlet is not necessary. The back purge inlet is
shut off by a check valve.
When sampling from Ex-zones, back
purging is only allowed with a gas suitable for the sampling point.

The special design of the optional heating of the M&C-probes version SP3100(V)
permits controlled heating of the complete filter housing, including the mounting flange. This ensures reliable operation
e
­ xternal to the process preventing the
temperature ­ alling below the dew-point.
f

Technical specifications and illustrations are without
obligation, subject to modifications. 10.04/11.12

M&C TechGroup Germany GmbH • Rehhecke 79 • 40885 Ratingen • Germany
info@mc-techgroup.com • www.mc-techgroup.com • Fon +49 2102 935-0 • Fax +49 2102 935-111

2.10

"

IRAN INDUSTRY EXPO

The largest online Industrial exhibition in Iran

 عضویت ورود   ENGLISH


اگر مجموعه شما جزو صنایع مادر و معظم در فیلد پالایشگاه ، پتروشیمی ، حفاری ، نیروگاه ، معادن و فلزات ، خودروسازی ، تولید مواد غذایی و.... می باشد لطفا درخواست خود را بر روی سربرگ به فاکس 88206264 و یا ایمیل enquiry@iranindustryexpo.com بنام شرکت مهندسی و بازرگانی مشگاد ارسال فرمایید.
اگر مجموعه شما جزو بنگاه های متوسط و کوچک در فیلد تولید ، بازرگانی ، مشاوره ، پیمانکاری ، دانشگاه ، پژوهشگاه ، توزیع ، فروشگاهی وکارگاهی می باشد ، پس از عضویت و با پرداخت هزینه ( به ازای هر درخواست معادل 50 یورو ) از خدمات زیر برخوردار خواهید شد :
  • پاسخ به پرسش های فنی و دریافت مشاوره از سازنده ، دریافت کاتالوگ و اطلاعات تکمیلی
  • دريافت پرفورما از شرکت سازنده
  • اطلاع از زمان تحويل و قيمت خالص كالا
  • اطلاع از هزينه هاي حمل و ترخيص و کارمزد تا تحويل كالا به انبار شما در هر نقطه از كشور
  • دریافت پیش فاکتوررسمی ( ارزی و یا ریالی ) به روش کارمزدی
*صدور پیش فاکتور رسمی فقط به نام شرکتهای ثبت شده که دارای کد بازرگانی معتبر باشند انجام پذیر است. در صورتیکه در حین مکاتبه با شرکت سازنده مشخص شود که دارای نماینده انحصاری و یا شعبه در ایران بوده و یا به به هر دلیل شرکت سازنده از فروش کالا به بازار ایران استنکاف نماید ارایه این سرویس متوقف و وجه دریافتی به حساب کاربر عودت می شود

ادامه