V&A Handheld Multi-function Calibrator VA740 Measurement & Analysis Instruments0 pages
Handheld Multi-function Calibrator
V&A®
INSTRUMENT
Specification:
■ Input
Voltage 30.000V/300.00mV
Range | Resolution | Accuracy | |
30.000V | 0-30.000V | ImV | 0.02%+3 |
300.00MV | -10~300.00mV | 10uV | 0.015%+3 |
Current 30.000mA
Range | Resolution | Accuracy | |
30.000mA | 0~30.000mA | luV | 0.015%+3 |
Resistance 500.00/5.0000k O
Range | Resolution | Accuracy | |
soo.oon | 0.00-500.00 | lOmD | 0.02%+10 |
5.0000Kf! | 0.0000-5.0000 | lOOmO | 0.015%+10 |
Thermocouple temperature TJEKSRBN -200-1800 degC
Resolution 0.1
Thermocouple | Source range | Setting resolution |
T(CC) | -200.0°C to+400.aC | 0.1 °C |
J(IC) | -200.0°Cto+1200.0°C | arc |
E(CRC) | -200.0°Cto+1000.0°C | 0.1 °c |
K(CA) | -200.0°Cto+1372.0°C | 0.1 °c |
S(PR10) | -10.0°Cto+1768.0°C | o.i °c |
R(PR13) | -10.0°Cto+1768.0°C | 0.1 °c |
B(PR30) | +330.0°Cto+1820.0°C | 0.1 °c |
N | -200.0°Cto+1300.0°C | 0.1 °c |
RTD PT100 PT1000 PT500 (385/392) Cu50 Cul0 Nil 20
Range | Resolution | Accuracy | |
PT100 | -200.0-800.0 | 0.1 | 0.5 |
PT1000 | -200.0-630.0 | 0.1 | 0.3 |
PT500 | -200.0-630.0 | 0.1 | 0.4 |
CulO | -100.0-260.0 | 0.1 | 1.8 |
Cu50 | -50.0-150.0 | 0.1 | 0.7 |
Ni120 | -20.0-260.0 | 0.1 | 0.4 |
■ Output
Voltage 20.000V/1 OO.OOmV
Range | Resolution | Accuracy | |
20.000V | 0-20.000V | 1mV | 0.02%+3 |
100.00MV | -10~100.00mV | 10uV | 0.015%+3 |
Current 24.000mA. 4~20mA%
Range | Resolution | Accuracy | |
24.000mA | 0~24.000mA | luV | 0.015%+3 |
Resistance 500.00/5.0000k O
Range | Resolution | Accuracy | |
soo.oon | 0.00-500.00 | 10mO | 0.02%+10 |
5.0000Kn | 0.0000-5.0000 | 100mO | 0.015%+10 |
Thermocouple TJEKSRBN -200-1800 deg C,
Resolution 0.1
Thermocouple | Source range | Setting resolution |
T(CC) | -200.0°C to+400.0°C | o.rc |
J(IC) | -200.0oCto+1200.0°C | arc |
E(CRC) | -200.0°Cto+1000.0°C | 0.1 °c |
K(CA) | -200.0°Cto+1372.0°C | o.rc |
S(PR10) | -10.0°Cto+1768.0°C | arc |
R(PR13) | -10.0°Cto+1768.0°C | o.rc |
B(PR30) | +330.0°Cto+1820.0°C | o.rc |
N | -200.0°Cto+1300.0°C | o.rc |
RTD : PT100, PT1000, PT500:(385/392 ),Cu50 ,Cu 10, Ni 120
Range | Resolution | Accuracy | |
PT100 | -200.0-800.0 | 0.1 | 0.5 |
PT1000 | -200.0-630.0 | 0.1 | 0.3 |
PT500 | -200.0-630.0 | 0.1 | 0.4 |
CulO | -100.0-260.0 | 0.1 | 1.8 |
Cu50 | -50.0-150.0 | 0.1 | 0.7 |
Ni120 | -20.0-260.0 | 0.1 | 0.4 |
► VA740
Key Features
< Application Features:
> Multiple functions integrated in one device.Voltage.
current .resistance .thermocouple temperature .RTD,
and also the capability to measure and output functions.
■ For industrial automation & control, laboratory and
other environmental design, production and maintenance.
> Easy operation interface, the keyboard input.
■ Wide viewing angle LCD display with backlight
i Memory and recall 10 group setting
i Scan mode/ Program mode
> Remote control. Software support
Atu,A 1
-' COM V/Q/RTD
, 3W
HJDW mA
More information online at
www.mastech.com.cn
"