FLEX6012A0 pages
FLEX6012A
RoHS
Input: single-phase: 115 – 230 Vac
Output: 12 Vdc 60°C
Efficiency up to 88%
Strong overload without switch-off
Flexible Power continuity : from 36 to 72 W
DIN Rail Mountable
Extremely small size
3 Year warranty
Features
Norms and certifications
Input Data
Nominal Input Voltage (2 x Vac)
Input Voltage range (Vac)
2
Inrush Current (Vn and In Load) I t
Frequency
Input Current (115 – 230 Vac)
Internal Fuse
External Fuse (recommended)
115 – 230 Vac
90 – 264
≤ 7 A ≤ 5 msec.
47 – 63 Hz ±6%
1 – 0.7 A
T4A
6 A (MCB curve B)
The CE mark in According to EMC 2004/108/EC and Low
voltage directive 2006/95/EC.
Output Voltage (Vn) Factory Setting ±3%
Adjustment range (Vadj)
Start up with Strong Load (capacitive load)
Turn-On delay after applying mains voltage
Continuous Current at 12 V up to 40°C (In)
Continuous Current at 12 V up to 50°C (In)
Continuous Current at 12 V up to 60°C (In)
Power Boost Current at 12 Vdc 50°C (In)
Current max. Overload ≅ 4Vdc (permanent)
Max current Short Circuit (Icc)
Hold-up Time ( min. Vac) 12Vdc 5A
Residual Ripple
Efficiency
Over temperature Protection
12 Vdc
10 – 15.5 Vdc
≤ 50.000μF
1 sec. (max)
4 A (115) 6 A (230)
3 A (115) 5 A (230)
2 A (115) 3 A (230)
7 A up to 3 min.
Imax=In50°Cx(1.8 - 2.2)
10 A
Typ. 20 msec
≤ 80 mVpp
≥ 88 %
Yes. Shut-down output
and automatic restart.
Yes, Continuous Mode
6
Yes, Continuous Mode
Yes (typ. 30 Vdc)
Yes
EMC Immunity
Output Data
Short-circuit protection
Dissipation power load max (W)
Over Load protection
Over Voltage Output protection
Parallel connection
Climatic Data
Ambient Temperature operation
Ambient Temperature Storage
Humidity at 25 °C, no condensation
In compliance to UL508.
According to IEC/EN 60950 (VDE 0805) e EN 50178 (VDE
0160) for assembling device. The unit must be installed
according to IEC/EN 60950.Input / Output separation: SELV
EN60950-1 6 Edition, and PELV EN 60204-1. Double or
reinforced insulation.
EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5,
EN 61000-4-6, EN61000-6-2
EMC Emission
EN61000-6-4, EN61000-3-2
Standards Conformity
EN 60204-1 Safety of Electrical Equipment Machines
Output derating Curve
Continuous Load
%
160
140
120
100
80
60
40
20
0
-10
0
10
20
30
40
50
60
70
°C
-25 up to +70 °C
(>60°derating 2.5% °C)
-40 up to +85 °C
95 % to 25 °C
Isolation Voltage (In / Out)
Isolation Voltage (In / PE)
Isolation Voltage (Out / PE)
Protection Class (EN/IEC 60529)
Reliability: MTBF IEC 61709
Pollution Degree Environment
Connection Terminal Blocks Screw Type
Protection class
Dimension (w-h-d)
Weight
Electrical Safety
3000 Vac
1605 Vac
500 Vac
IP 20
> 500.000 h
2
2,5 mm (24 – 14 AWG)
I with PE connected
50x120x50 mm
0.3 kg approx.
General Data
All specifications are subject to change without notice
"