AVF7000 Series0 pages
ALIAVTX
®
Vortex Flowmeter
Model AVF7000 Series
GENERAL
ALIAVTX
AVF7000 is a Vortex Flowmeter based on Von Karman
theory of vortices generated by a bluff body in the pipe. The number
of vortices are linearly proportional to the volumetric flow in the pipe.
The AVF7000 is versatile flowmeter widely used for Gases, Steam &
Liquid applications. There are no moving parts and comes with either
flange or wafer connection. Standard configuration has local
indication for flowrate and total flow as well as 4-20mA with HART
signal and pulse output functions. The microprocessor design can
filter out erroneous signals as well as interfence caused by pipe vibration.
FEATURES
Simplified setup and self-diagnostic functions
Auto. Temperature & Pressure compensation
4-20mA with HART signal and pulse outputs, user selectable
A very wide selection of sizes
Wide temperature range up to 420 °C
Non-volatile memory for setup and calibration
STANDARD SPECIFICATION
: 15,20,25,32,40,50,65,80,100,125,150
Size
Local Display
200,250,300,350,400,450,500mm
Measuring Range
: 6 digit flowrate
: Steam - 1.6 to 540,000 Kg/Hr
: Gas - 3 to 46,000 M3/Hr
: 8 digit Totalizer
Current Output
Accuracy
Pulse Output
Unit
Communication
: HART (Compatible)
Data Storage
: Operation parameter and totalizer
: Nm3/h, Nm3/m, Nm3/s, m3/d, m3/h, m3/m
m3/s, l/h, l/m, l/s, t/d, t/h, t/m, kg/d, kg/h
or RS485 (MODBUS Protocol)
kg/m, kg/s, g/h, g/m, g/s
Repeatability
: Flange / Wafer
figures are stored by EEPROM for more
: +/-0.2% value of reading
Process Connection
Flange type : JIS 10K / JIS 20K / JIS 40K
ANSI 150# / ANSI 300# / ANSI 600#
than 10 years
Housing Material
Temperature
Cable Entry
: Standard :M20 Option:1/2"NPTF
: 12-32 VDC
KeyPad
: 3 internal keys for programming
: Ni-MH Battery (3 years working Hours)
: -40 ~ +280 °C (Standard)
: -40 ~ +420 °C (Optional)
Ambient Temperature : -20 ~ +60 °C
Pressure
: 78 Kg/cm2 (Max.)
Protection Class
: IP 65
: Explosion Proof, Exd IIC T6
: Aluminum Alloy
Power supply
DIN PN 10 / PN 16 / PN25 / PN 40
Wafer type : DN40~DN250 without Temp. / Pressure Sensor
: Scale Pulse
Load : 1000 Ω - 5000 Ω
Liquid : +/-0.7% value of reading
Gas & Steam : +/-1.0% value of reading
: 4-20 mA (2 wire) with HART signal
Load : Max. 1000 Ω
: Liquid - 0.3 to 4950 M3/Hr
: Stainless Steel 301 / 304 / 316
Material
: 2 lines LCD
and display control
Option
Pressure Sensor : Pressure compensation
Signal output : 0-30 mV DC (20 uA Power supply)
Temperature Sensor : Temperature compensation
Signal Output : PT1000 (2 wires)
: Intrinsically Safe, Eex ia IIC T4
ALIA GROUP INC.
113 Barksdale Professional Center, Newark, DE 19711, USA
TEL : + 1 - 302 - 213 - 0106
FAX : + 1 - 302 - 213 - 0107
URL : www.alia-inc.com
E-mail :alia@alia-inc.com
AVF7000V1.1.9.A4.en