PR/TIMER0 pages
600 SERIES
17.5MM DIN RAIL TIMER
EOOXU
6Q0ST
GQOSD
Description
Modes*
Time Ranges
13 Functions 10 Time Ranges Single Function 10 time Ranges Star Delta
Accuracy/
Setting
Repeat
Reset
Output Contacts/
Relay Rating
Supply Voltage
Order Code
Certification
A, B, C, Ci, D, E, F, H, I, J, K, Ai, Bi
ON delay
0.1 -1 sec, 0.3 - 3 sec, 1-10 sec, 3 - 30 sec
0.1 -1 min, 0.3 - 3 min, 1-10 min, 3 - 30 min
0.1 -1 hr, 0.3 - 3 hr
Setting: ±5% of Full Scale
Star - Delta
Runup time:
3 sec - 30 sec,
6 sec - 60 sec
Change over: 50/100 msec
Repeat: ±0.5%
On interruption of power; Reset time < 100 msec
1 C/O (SPDT), NO/5A, NC/3A@250VAC
12-240VDC, 20-240VAC
AC: 50/60 Hz
600XU-A-1-CU
C€ .®- V?,
240V AC, 110V AC, 24V AC/DC
AC: 50/60 Hz
600ST-CU
230V AC, 110V AC, 415V AC
AC: 50/60 Hz
600SD-110-CU
600SD-2-230-CU
60QDT
15 Functions, 8 Time Ranges
A, B, C, D, E, F, H, J, K, L, P, 0, R, T, U
0-99.9 sec/min/hr
0 - 999 sec / min / hr
0 - 9:59 min:sec,
0-9:59hr:min
Setting: ± 0.1 % of set time or
±50msec (whichever is greater)
For Y contact operation:
+100msec
Repeat: ± 0.1 %
Front Key, On interruption
of power; Reset time < 100 msec
1 C/O(SPDT),8A@250VAC
20-240V AC/DC
AC: 50/60 Hz
600DT-CU
General Specification
Power Consumption: 4VA max, Temperature: Operating: 0 to 50T (32 to 122"F), Storage: -20 to 75°C (-4 to 167°F),
Humidity (non-condensing): 95% RH, Protection Level: Casing: IP40, Connecting terminals: IP20
Mounting: DIN RAIL Mounting, Size: 17.5 (W) x 90(H) x 60(D)
600XU
600DT
A - On delay, B - Interval, C - Repeat cycle equal OFF first, CI - Repeat cycle equal ON first, D - Pulse output 500ms fixed, E - Delay on break, F - Delay on make/Delay on break,
H - Interval after break, I - Single shot, J - Retrlggerable Single shot, K - Latching relay, AI - Delay on break with Totalise, BI - Interval with Totalise
A - On delay, B - Interval, C - Asymmetrical cyclic OFF first, D - Asymmetrical cyclic ON first, E ■ Repeat cycle equal OFF first, F - Repeat cycle equal ON first, H - Pulse output, J ■ Delay on break,
K - Delay on make/Delay on break, L - Interval after break, P - Single shot, Q - Retrlggerable Single shot, R ■ Latching relay, T - Delay on break with Totalise, U - Interval with Totalise
Timing Diagram
Function: ON Delay
Supply
Voltage
Function: Interval
T - set time
T=set time
Function: Cyclic Equal OFF First
□
Supply
Voltage
NO Contact [
NC Contact I
Function: Delay On Break
Supply
Voltage
Control
Contact Y1
NO Contact
NC Contact
Function: Cyclic Equal OFF First (with Y Contact) Function: Cyclic Equal ON First
Supply
Voltage
Control
Contact (Y1)J
NO Contact
NC Contact
T = set lime
i: Applicable for EODXU only
Function: Delay On Make / Break
T = set time
Function: Interval After Break
Supply Voltage
Control Contact |
Y1
NO Contact
NC Contact
T = set time; tl <T
T= Set time; t1 <T
Function: Latching Relay
Supply Voltage I ■
(u)
Function: Delay on break with Totalise
Supply rj
NO Contact
NC Contact
Function: Interval With Totalise
Supply
Voltage (U)'
Control r
Contact Y1
NO Contact [
NC Contact I
11 +12= T; T = Set time
t1+t2=T;T = Set time
Function: Asymmetrical Cyclic OFF First
Supply C
Voltage
NO Contact
NC Contact I
Function: Asymmetrical Cyclic ON First
Supply LP
Voltage
T1 = OFF time ;T2 = ON time
Nolo: Applicable for 600DT only
T1 = ON time; T2 =
Note: Applicable for NDDT only
Function: Pulse Output
Supply
Voltage
Function: Pulse Output (500ms fixed)
Supply
Voltage
T1 = Off time; TZ = On time
Nolo: Applicable for 600DT only
Function: Single Shot
Supply
Voltage
Control
Contact Y1
NO Contact
NC Contact
NO Contact [
NC Contact I
T = Set time; P = 500msec
Note: Applicable for BOOXU only
Function: Retriggable Single Shot
Function: Star
Supply Voltage C
Star Relay
(NO Contact)
Delta Relay
(NO Contact) 1
T1= Run uptime
T2= Pause time
www.
.selec.com
55 SERIES
PLUG / PANEL MOUNT TIMER
Series 55:
COMMON FEATURES:
Mounting; Plug / Planel Mounting
RESET; On interruption of power
(Reset time: Less than 100ms)
LED INDICATION : 1) Power, 2) Relay
ACCURACY: For 55XU, M(V1.1), ES, XC:
Setting: ±5% of full scale
Repeat: ± 0.5% or 50 ms (whichever is greater)
RELAY RATING: For 55XU, M(V1.1), ES, XC:
5 A@ 230V AC/24V DC, resistive load
500XC
500X1
DESCRIPTION
Modes
Base Type
Time Ranges
Accuracy:Setting
Cyclic with unequal On time & Off time
2 functions, 12 ranges
Reset
Output Controls
Relay rating
Supply Voltage
Temperature
Humidity (non- condensing)
Weight
Mounting
Order Code
Certification
Asymmetrical Cyclic ON first or OFF first
P8- 8 pin plug, T- Screw Terminal
1/10 sec/min/hr for both On & Off time
55XC-P8-CU
55XC-T8-CU
ON Delay/ Interval
P8- 8 pin plug, T- Screw Terminal
1/3/10/30 sec/ min/hr
±5% of F.S
±0.5% or 50ms
On Interruption of power; Reset< 100ms
2 C/O (DPDT)
5A @ 230V AC / 24V DC resistive
20 to 240V AC,12 to 240V DC,(AC:50/60 HZ)
Operating: Oto 50°C(32 to 122°F), Storage: -5 to 50°C(23 to 122°F),
95% RH
80gms
Plug/Panel
55XU-P8-CU
55XU-T8-CU
C€ <<§>»> j/
Timing Diagram
Function: ON Delay
Supply
Voltage
Function: Interval
Supply
Voltage
Start
Function: Asymmetrical Cyclic OFF First
□
Supply
Voltage
NO Contact [
NC Contact I
T1=0FFtime;T2 = 0Ntime
Function: Asymmetrical Cyclic ON First
Supply HP
Voltage
NO Contact
NC Contact
T1
ON time ;T2 = OFF time
Terminal Connections & Dimensions
Panel Mount Type
500XC/55XU
8 Pin Socket
7mm
70.5mm
Panel Cutoul
46mm
79mm
500XC/55XU
Panel Mount Type
©1 © I © I ®T®]
NClL^> OJno1L^-^ ol102
COM1 NC2 COM2
© I © I ® I ®T@1
Lt^N
500XC/55XU
8 Pin Socket
NC1 „ „ NC2
©-
N01 W n "02
LW$ ®i—^
SELEC
Creating Best Value
Protection Relays (Analog/ Digital)
• Phase • Voltage • Current • Frequency • Earth Leakage
Creating Best Value
For more information visit us at -j^WWW.SeleC.COITI
Selec Controls Pvt. Ltd. (An ISO 9001:2008 Company)
Regd. Address:
EL-27/1, Electronic Zone,
TTC Industrial Area, MIDC, Mahape,
Navi Mumbai 400710, INDIA
Tel.:+91-22-4141 8419/8430
Fax: +91-22-28471733
Tollfree: 1800 227353 (BSNUMTNU,«
Email: sales@selec.com
Selec Controls USA.,Inc.:
203 main Street # 205
Flemington,
NJ 08822, U.S.A.
Phone: +908-627-2149,
Fax: +908-968-0940,
Email: usa@selec.com,
Web: www.selecusa.com
Selec GmbH:
Mollwitzstrasse 2,
D-14059, Berlin,
Tel:+49 3030111870,
Fax.:+49 303011187-77,
Email: europe@selec.com
Web: www.selec-europe.com
Time Relays
600 Series
A class apart
The most advanced features products... worldwide
TIMERS
600XU - Multifunction
600ST - Cost Effective
600SD - Start Delta
600DT - Digital ( SV+PV display)
" selec
4 \ f 7
-Tfjf
CERTIFICACION:
Vi V LISTED'
US
LISTED4STG
IND. CONT.EQ.