Product_Description_GKV0 pages
Product and Process Description
1/2
SILOXA frame-mounted gas supply system with gas drying
and gas compression module and controller, GKV model,
set up for outdoor installation
Sizes/system components
– A total of 12 performance classes, with gas ow rates
ranging from 180 to 2,100 Nm3/h
– The components are mounted on a frame
Design features (basic version)
SILOXA GKV schematic drawing
Product description
The GKV is based on the same ingenious concept
as the GCKV: consistent bundling of all key functional units that are needed to reliably supply the gas
engines with the biogas produced. Unlike the GCKV,
however, where all system components are housed
in a closed container, the GKV's components such as
the gas cooler, condensate trap, liquid coolant circuit,
water cooler (required depending on the size) and
compressor are xed on a steel frame. A contactor
control handles the monitoring and control of all integrated assemblies.
The all-in-one nature of the GKV means the addition
of only one more compact unit to the adjacent assemblies of the biogas plant, gas storage tank and
gas utilisation system.
The user-friendly and reliable GKV is available in 12
performance classes, with gas ow rates ranging
from 180 to 2,100 Nm3/h.
Combining the gas supply technology in a central system is advantageous because it reduces the investment
volume for the operator, simplies planning, guarantees
reliable operation and saves on maintenance later.
The unit is fully assembled in the factory by SILOXA
engineers.
– Frame
– Gas cooler
– Water cooler
– Liquid coolant circuit
– Condensate trap
– Cold insulation
– Compressor
– Control cabinet
– Factory assembly
– Technical documentation
Options
– Version for indoor installation
– Autonomous hot water supply for heating
– Biogas analysis
– Frequency converter
– Gas heating
– Assembly and commissioning
– Pipe with buttery valve (manually operated)
extending to 10 cm above ground level
– Biogas oxygen monitoring system
– TÜV certication for pipework
– Compression by 200 or 280 mbar
– Weld neck ange instead of loose ange
Safety features
– All the components that come into contact with gas
are electrostatically dissipative
– The system complies with the ATEX requirements for
using biogas and with TRBS 2153 (technical rules
for operational safety: prevention of ignition hazards
due to electrostatic charges)
Siloxa Engineering AG
Katernberger Strasse 107 | 45327 Essen | Germany
Tel. +49 (02 01) 2 89 51-0 | Fax +49 (02 01) 2 89 51-29
E-mail: vertrieb@siloxa.com | Web: www.siloxa.com