Series D100 Specs0 pages
Series D100
SERIES P010
Dual DC Power
Supply
OEM Oscillator/
Demodulator
The Series D100 power supplies are regulated, preset voltage
sources, ideally suited for DC excited transducers, discrete and
IC function modules. All components are encapsulated to provide
reliable continuous operation to rated specifications in laboratory
and factory environments. They are equipped with an on-off
switch, line cord, binding post terminals, rubber feet and a #440 tapped hole located on the bottom side for permanent
mounting. The hole is connected to earth ground via the power
line cord ground terminal.
CONNECTION AND MOUNTING
Dual voltage power supplies allow the user to choose the
transducer excitation voltage; for example, Model D12.200 can
be used to power a transducer with 12 VDC or 24 VDC. To
excite the transducer with 12 VDC, connect the transducer
+INPUT and -INPUT to the power supply +V and COM
terminals, respectively (or to the power supply COM and -V
terminals, respectively). To excite the transducer with 24 VDC,
connect the transducer +INPUT and -INPUT to the power supply
+V and -V terminals, respectively.
PINOUT
DIMENSIONAL DRAWING
The Series P010 contains a standard Berg
model #66953-06 connector for easy
installation on user’s PC Boards. For
applications where the electronics will be
subject to vibration, it is recommended that
the Series P010 board be clamped onto the
user’s main PC board assembly.
PIN
1
2
3
4
5
6
A
B
C
D
E
F
KEY FEATURES
• Compatible with DC LVDTs and ADTs
• Short Circuit Protected
• High Regulation
FUNCTION
LVDT Output, Non-Lead End
Oscillator Output High
Not Used
Unfiltered Demodulator Output
-15 VDC Power Supply
Common
LVDT Output, Lead End
Not Used
Not Used
Not Used
+15 VDC Power Supply
Analog Output
• Compact Package
INTERCONNECTION DIAGRAM
COMMON SPECIFICATIONS
INPUT
105 to 125 VAC, 50 to 400 Hz
STORAGE TEMPERATURE
-40°F to +185° (-40°C to +85°C)
OUTPUT VOLTAGE TOLERANCE
±1% (Fixed)
TERMINATION
Line Cord, 3-wire, 5 feet long, terminated in line
plug with earth ground.
REGULATION
Line 0.05% Max., Load 0.10% Max.
OUTPUT TERMINALS
3-Binding Post, 6-Way
TEMPERATURE COEFFICIENT
0.02% /°C Typ.
Red - Positive Voltage
RIPPLE AND NOISE
1m VRMS Max.
Black - Common
I/O ISOLATION
50 MegaOhms
OVERCURRENT PROTECTION
Current Limiting: Either input to
common or other output, indefinitely
-13°F to +160°F (-25°C to +71°C)
BLOCK DIAGRAM
OPERATING TEMPERATURE
Violet - Negative Voltage
DIMENSIONS In. (mm) WxLxH
2.5 (64) x 4.45 (113) x 1.25 (32)
APPROXIMATE WEIGHT
1.6 lbs.
SPECIFICATIONS
MODEL NUMBER
D12.200
D15.200
OUTPUT, VDC
±12
±15
CURRENT, mA
200
200
Tel: 800-828-3964
860-872-8351
Fax:
Web:
Tel: 800-828-3964
860-872-8351
72
04C
34 in pb spreads
860-872-4211
www.transtekinc.com
19
04C
Fax:
Web:
860-872-4211
www.transtekinc.com
69
04C
4/30/04, 8:42 AM
04C
"