Isolation-/Supply Unit LDX2 - U2850 pages
Isolation-/Supply Unit LDX2
for Ex - flow sensors of type
category 1 (zone 0)
in protective system
Ex ia IIC T6
v-sensors FA
U285_LDX2_D_e_110718
v-sensors VA
category 2 (zone 1)
in protective system
Ex ia IIC T6
(Ex ib IIC T6)
v-sensors FAR category 2 (zone 1)
in protective system
Ex ia IIC T6
(Ex ib IIC T6)
The Isolation-/Supply Unit LDX2 is a Exinput unit for non-Ex flow evaluation
units of Höntzsch. Therefore it is used
for measuring flow in hazardeous
areas.
For the Ex input of isolation-/supply
unit the following is valid:
the intrinsically safe circuit is conductively decoupled from both the power
supply and the output.
Installation note
The operation of the intrinsically safe
isolation-/supply unit LDX2 is only
permitted outside hazardous areas.
The isolation-/supply unit LDX2
supplies the intrinsically safe flow
sensor VA or FA and conductively
decouples the sensor signal from the
output signal.
Conformity to standards
The isolation-/supply unit LDX2 meets
the requirements of European
standards:
EN60079-0 Common standards
EN60079-11 Intrinsic safety
EN60079-26 Special requirements
category 1G
1 of 2
Installation in a CE approved
housing
As required, the isolation-/supply unit
LDX2 can be built into a CE approved
EMC housing along with a non-Ex
flow evaluation unit in LDG housing.