Thermal Flow Sensor TA10/15 Ex-d - U3520 pages
Thermal Flow Sensor
nnnnTAlO/15 ... ZG1 Ex-d
nnnnhontzsch
nnnnflow measuring technology
nnnnThermal flow sensor TA10/15 ... ZG1 Ex-d with integrated,
nnnnconfigurable transducer UTA in pressure-proof Ex-d enclosure
nnnnfor application in potentially explosive atmospheres
nnnnSensor TA10/15 ... ZG1 Ex-d
nnnnca.205 | |||
fM CO |
SFB ZG5
nnnnMuffe
nnnnDrawing 1: Connection on sleeve
nnnn(Muffe) with inside thread provided
nnnnon site
nnnnMeasurable variables
nnnnstandard velocity Nv, standard
nnnnflow rate NV/t, mass flow
nnnnproportional
nnnnnorm:
nnnntemperature tn = +21 °C,
nnnnpressure pn = 1014 hPa
nnnnFunctional principle
nnnnflow measurement according to 1
nnnnthe heat transfer method
nnnntemperature-compensated
nnnnmeasuring
nnnnDesign / Sensor
nnnnprobe with integrated
nnnntransducer in the Ex-d
nnnnconnection enclosure
nnnnthin film sensor element
nnnnGases
nnnnpure gases, gas mixtures:
nnnnair, nitrogen, methane, natural
nnnngas, hydrogen, argon, carbon
nnnndioxide, helium, sulphure
nnnnhexafluoride, landfill gas ...
nnnncalibration can be carried out
nnnnwith a multitude of gases or gas
nnnnmixtures to achieve the lowest
nnnnmeasuring uncertainty
nnnnAdvantages
nnnnapplication in potentially
nnnnexplosive atmospheres:
nnnnCategory 1/2 G (Zone 0/1) and
nnnnCategory 1/2 D (Zone 20/21)
nnnnhigh measuring dynamics Nv
nnnn(up to 1 : 1000)
nnnnlow measurement uncertainty,
nnnneven at lowest flow velocities
nnnndirect air/gas mass flow
nnnnproportional measuring;
nnnnadditional measurement of
nnnnpressure and temperature is not
nnnnnecessary
nnnnsensor has no moving parts
nnnnstainless steel sensor housing
nnnngreater temperature and
nnnnpressure resistance ranges
nnnnlow installation costs
nnnnminor pressure drop thanks to
nnnnsmall dimensions
nnnndurable
nnnnsterilisable (material-
nnnnresistance of sensor allowing)
nnnneasy configuration via HART®
nnnninterface
nnnnExamples of application
nnnnmeasuring
nnnn- in Ex applications
nnnn- of air velocity
nnnn- of compressed air and gas
nnnnconsumption as well as
nnnnleakage flows
nnnn- of laminar flow in safety
nnnncabinets or machines
nnnn- in exhaust air and burner
nnnnsupply air
nnnn- in air-conditioning applications
nnnn- in air in low vacuum range
nnnnwith pressures greater than
nnnn200 hPa abs.
nnnnParticles, humidity in the gas
nnnncharges in the gas caused by
nnnnparticles such as dust and fibres
nnnndo not affect the measurement,
nnnnas long as there is no abrasion or
nnnndeposits on the sensor
nnnndeviations in values as a result of
nnnnvariable air humidity in normal
nnnnatmospheric conditions are
nnnncovered by the measuring
nnnnuncertainty specifications
nnnnU352_TA1015 Exd_DoP_e_120417 http://www.hoentzsch.com 1/6
"