µP-ASD in LDG 30 housing - U2280 pages
µP-ASD in LDG30 Housing
Evaluation unit with display and keypad
for connection of vane wheel flow sensors FA which do not sense the direction
of flow
for measuring actual flow velocity
for determining actual volume flow,
optionally also standard volume flow and
mass flow …
Once you have received your delivery
please consult the accompanying
Technical Data Sheet that contains information specific to your order and also
refer to the documents listed in the
manual. The data in these documents
supplements the following information.
Hardware
The hardware of the evaluation units is
available in a number of different
variations, adapted to suit all types of
user requirements. Each variation is
distinguished by a specific combination
of hardware elements. Below are the
hardware elements for the
µP-ASD in LDG housing. Other hardware elements are also available: see
data sheet Hardware.
U228_uPASDLGD30_D_e_040531
Cylinder probe
Measuring tubes FA·Di...
Input v/FA for v-transmitters FA:
Höntzsch vane wheel flow sensors as
cylinder probes, which do not sense the
direction of flow, measuring tubes…
Connection cable: 2 or 3 conductors
with overall shielding. Measurable
variable: actual velocity.
Housing Miniature housing LDG30
W/H/D = 100/75/110 mm for 35 mm
standard assembly rails. See also data
sheet Housings.
Connection Terminals
Terminal connections
Keypad 12 multifunctional keys
Display LCD 16·2·5.5
Liquid crystal display module. Dot matrix,
double-spaced alphanumeric, 16
characters/line, character height 5.5 mm
1 of 2
Analog Output
The software determines the allocation of an analog signal to a specific
measurable variable, outcome value
or measuring range.
20 mA – 500 W
0/4…20 mA
Load resistor max. 500 W
0…10 V optional
Output signal 0…10 V,
Impedance 1 kW
Power supply 230 VAC
230 V +6/-10% 50/60 Hz
Current consumption less than 100 mA
Power supply 24 VAC optional
24 V +6/-10% 50/60 Hz
Current consumption less than 500 mA
Power supply 24 VDC optional
20…30 V DC with DC/DC converter
Current consumption less than 500 mA
Output relay optional
The software determines the allocation of a relay function to a specific
event or status. Relay output with
1·operation/mean/non-operation,
max. 3 W, current-carrying capacity
28 V
Working temperature range
of all hardware elements 0…+50 °C