Product upgrades may occur without prior notice for quality purposes.
Note : The MS Relay Box was designed for the Pulsarlube MS unit only.
Product warranty will be null &void if any other type of unspecified adapter or converter is used.
Pulsarlube MS unit turns “On” or “Off” in synchronization with the equipment on which it is installed. It will dispense
the preset amount of grease as long as the machine is operating. If the equipment is not on, then Pulsarlube MS
unit goes into “stand-by mode” and does not dispense lubricant until the machine goes back into operation.
The MS unit is not an externally powered unit. It operates on its own battery Power. Battery should be replaced
every time you replace the grease pouch. The MS unit will turn ON/OFF via its Relay Box in accordance with the
related equipment power signal.
The MS functioning process
Operating Principles
Main Unit specification
Relay Box Specifications
Operating the Pulsarlube MS
MS
Pulsarlube MS (Machine Synchronized Lubricator)
10 20 30
1) Month setting 2) Working for 10 days 4) Working again for 20 days
5) Finished
Total days
LCD RED LED Signal
lamp blinking
40
250 250 250 250
3) Off for 10 days
Power on
250 250 250
Models Available 125cc, 250cc or 500cc (ML500, OL500)
Operating Pressure 20Kgf/ (280psi)
Operating Temp Range 15Ž ~ 60Ž (5¢ªF ~ 140¢ªF)
Multi Point Lubrication Up to 8 points
Power Source DC 4.5V Replaceable Alkaline Battery
Other Functions Same as the Pulsarlube M lubricator
Item Description Image
Voltage Rate Input
Main Unit Side
Input
Output
AC 100~440V, 0.5W
50 ~ 60Hz
Voltage Rate Output Signal (Open collector Type)
Power ON Indicator Red LED
Relay CBaosxe D siimzee(nmsmio)ns (mm) 8855(D(D) )x x 4 499(W(W) )x x 3 322(H(H))
1M
4.5M
90mm
Item Description Image
Wire
Length
Power
Supply
Side
Doc No : 3208 REV . 000709