G100E0 pages
G100E Series
Low Cost, 1W MiniDIP
Single & Dual Output
DC/DC Converters
Electrical Specications
Specications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specications subject to change without notice.
Key Features:
• 1W Output Power
• Compact “MiniDIP” Case
Input
Parameter
Conditions
Input Voltage Range
• EN 60950 Approved (UL)
• Single & Dual Outputs
• 1,000 VDC Isolation
• >3.5 MHour MTBF
• 24 Standard Models
• LOWEST COST!!
Input Filter
Reverse Polarity Input Current
Min.
Typ.
5 VDC Input
4.5
5.0
12 VDC Input 10.8
12.0
24 VDC Input 21.6
24.0
Internal Capacitor
Max.
5.5
13.2
26.4
Units
0.3
A
Max.
±3.0
±1.0
Units
%
%
%
VDC
Output
Parameter
Output Voltage Accuracy
Output Voltage Balance
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Output Power Protection
Temperature Coefcient
Output Short Circuit
Conditions
Min.
Typ.
±1.0
Dual Output , Balanced Loads
±0.1
For Vin Change of 1%
±1.2
See Model Selection Guide
Single Output, See Note 3
75
Dual Output, See Note 3
50
120
±0.02
Momentary (1.0 Sec.)
100
750
±0.03
mV P - P
%
%/ºC
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Min.
1,000
1,000
Typ.
Max.
Units
VDC
M
pF
kHz
Max.
+85
+125
Units
ºC
ºC
95
%
60
100
Environmental
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
MicroPower Direct
Parameter
MTBF
Safety Standards
Safety Approvals
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
0.79 x 0.39 x 0.28 Inches (20.0 x 10.0 x 7.0 mm)
Non-Conductive Black Plastic (UL94-V0)
0.07 Oz (2.1g)
Reliability Specications
292 Page Street
Suite D
Stoughton, MA 02072
USA
Conditions
Absolute Maximum Ratings
Conditions
Min.
Typ.
MIL HDBK 217F, 25ºC, Gnd Benign
3.5
UL 1950, EN 60950
UL, cUL; File No. E245422
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
Internal Power Dissipation
5 VDC Input
12 VDC Input
24 VDC Input
1.5 mm From Case For 10 Sec
All Models
Min.
-0.7
-0.7
-0.7
Typ.
Max.
Units
MHours
Max.
9.0
18.0
30.0
300
450
Units
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
ºC
mW