PAK75-PAK200 Series0 pages
AC-DC Converter
PAK75/PAK100/PAK150/PAK200 Series
75-200W Active PFC
Single Output
www.powersolve.co.uk
Features
•
•
•
•
•
•
•
Universal AC Input with active PFC
Green Design, no-load power consumption <0.7W
Short Circuit / Overvoltage / Overload Protections
High Efficiency, Long Life and High Reliability
Operating Temperature range -20°C to +70°C
Power On LED Indicator
100% full load burn-in test
PAK75 & PAK100: 157(L) x 98(W) x 42(H) mm
PAK150 & PAK200: 197(L) x 98(W) x 42(H) mm
Electrical Specification
Input Voltage
Power Factor
AC Input Current (typ.)
Inrush Current
Leakage Current
Output Voltage
Output Current
Overload Protection
Overvoltage Protection
Over Temperature Protection
Operating Temperature Range
Operating Humidity
Storage Temperature Range
Storage Humidity
Temperature Coefficient
Vibration
Safety Standards
Green Energy
Withstand Voltage
Isolation Resistance
EMI Conduction & Radiation
Harmonic Current
EMS Immunity
Cooling
Dimensions
Weight
90-264VAC full range, 50-60Hz / 127-370VDC
>0.9 @ 230VAC / >0.98 @115VAC
1A @ 115VAC / 0.5A @ 230VAC (PAK75)
1.2A @ 115VAC / 0.6A @ 230VAC (PAK100)
1.8A @ 115VAC / 0.9A @ 230VAC (PAK150)
2.3A @ 115VAC / 1.2A @ 230VAC (PAK200)
20A @ 115VAC / 45A @ 230VAC (PAK75 & PAK100)
30A @ 115VAC / 55A @ 230VAC (PAK150 & PAK200)
<2mA @ 230VAC
See Table
See Table
>105% of rated output power. Hiccup mode, recovers automatically when fault is removed
115-150% rated output voltage. Output latches off
90°C ±5°C. Shuts down output, re-power on to recover after temperature goes down
-20°C to +70°C. Above 50°C, derate linearly to 50% load at 70°C
20-90% RH non-condensing
-40°C to +85°C
10-95% RH non-condensing
±0.03%/°C (0-50°C)
10-500Hz, 5G 0.5 Oct/min., for 60 mins, along X,Y & Z axis
UL60950-1, TUV EN60950-1 approved
CEC Single Voltage External AC-DC & AC-AC power supplies eligibility criteria (version 1.1)
I/P-O/P: 3KVAC (4242VDC), I/P-FG: 1.5KVAC (2121VDC), O/P-FG: 0.5KVAC (707VDC)
all for 1 min.
I/P-O/P, I/P-FG, O/P-FG: 100MΩ / 500VDC
EN55022: 1998+A1 : 2000+A2 : 2003 Class B
EN61000-3-2: 2000+A2 : 2005 Class A, EN61000-3-3 : 1995+A1 : 2001
EN61204-3 : 2000, EN50204 : 1998+A1 : 2001+A2 : 2003 light industry level, criteria A
Free Air Convection (PAK75, PAK100 & PAK150)
Internal Fan (PAK200)
157(L) x 98(W) x 42(H) mm (PAK75 & PAK100)
197(L) x 98(W) x 42(H) mm (PAK150 & PAK200)
0.65Kg (PAK75 & PAK100)
0.70Kg (PAK150)
0.80Kg (PAK200)
Notes:
1. All parameters NOT specifically mentioned are measured at 230Vac input, rated load and 25°C ambient temperature
2. Ripple and noise are measured at 20MHz bandwidth by using a 12” twisted pair wire terminated with a 0.1µF ceramic & 47µF electrolytic capacitors across the output
3. Derating is required at low input voltages. Derate linearly to 90% load at 90Vac under 100Vac input
4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC Directives
Powersolve Electronics Ltd. 8A Arnhem Road, Newbury, RG14 5RU. England
Tel: 01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk