PSO80-PSU80 Series0 pages
A C - D C C o n v e r ters
www.powersolve.co.uk
PSO80/PSU80 Series
Dual & Triple Outputs
Up to 80 Watts
Features
• Power Factor Correction
• Wide Universal Input Voltage of 90-264VAC
• Dual or Triple DC Outputs
• Industry Standard 5 x 3” footprint
• Available as Open PCB or in Aluminium U Channel
• Full Safety Approvals
• EMC to FCC Part 15 Class B & CISPR-22 Class B
Electrical Specification
AC Input
90-264VAC, 47-63Hz
Power Factor Correction
0.95 Minimum
Input Current
2A Max, Low Line, Full Load
Inrush Current
30A Max, Cold Start, 230VAC Input
Efficiency
80% Typical
DC Outputs
See table
Line Regulation
0.5% Typical, 1% Max
Load Regulation
See table
Over Voltage Protection
Output 1 of Multi Output Models, 112-132% V Nominal
Over Current Protection
110-150% Nominal Output Power
Transient Response
4mS, Full Load to 50% Load
Hold Up Time
16mS Min, 110V AC Input, Full Load Output
Start Up Time
1 Sec Typical, 2 Sec Max
Ripple & Noise
1% Typical, 2% Max
Earth Leakage Current
0.45mA Max
Operating Temperature
0 to 70ºC, Derate Linearly from 100% Load at 50ºC to 50% Load at 70ºC
Storage Temperature
-40 to +85ºC
Relative Humidity
95% Max Non Condensing
EMC
FCC Part 15 Class B, CISPR-22 Class B
Safety Approvals
UL, cUL60950, TUV/GS(EN60950), CE
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk