Power Relays 295 series0 pages
Specifications subject to change without notice
295 POWER RELAY
295
Applications
Rev 11/07/06
Page 1 of 2
Power relay rated for 20/10 amps Tungsten @ 120/240 VAC
(2.4 KW) switching on all contacts in a DPDT configuration.
• Traffic controller equipment
Features
• 20 amp Tungsten switching on all contacts
• Molded class F (155º C) coil construction
• Contacts designed for superior switching performance
• Contact wiping action results in long contact life
• PPS molded panel for superior physical characteristics
Rynite® is a registered trademark of EI du Pont de Nemours and Company
Contact Data Expected Life
• Configuration: DPDT • Electrical: 200,000 operations min. @ rated load
• Material: Silver Cadmium Oxide • Mechanical: 5,000,000 operations min. @ no load
• Size: 3/8” diameter Dielectric Strength
Contact Ratings • Across open contacts: 1200 VRMS
• Tungsten load rating • Contacts to coil: 2200 VRMS
• 20 Amps @ 120 VAC (2.4 KW) • Contacts to frame: 2200 VRMS
• 10 Amps @ 240 VAC (2.4 KW) • Pole to pole: 2200 VRMS
Coil Data Mechanical Data
• Nominal input voltage: 120/110 VAC, 60/50 Hz • Operating position: Any
• Nominal coil power: 7.0 VA • Mounting: Cinch-Jones 2408 8 pin socket or equiv.
• Coil resistance: 970 Ohms ±10% • Terminals: 0.250” x 0.055” (6.35mm x 1.40 mm)
• Coil insulation: Molded Rynite® class F system • Insulation material: Thermoplastic 94V-O rating
• Insulation resistance: 100 Megohms minimum • Cover material: Clear Polycarbonate 94V-2 rating
• UL insulation system file No: E74443 • Cover protection category: 40 IP rating
Operate Data • Weight: 7.0 oz. (198 grams) approx.
• Pull-in voltage: 75% of nominal voltage Agency Information
• Drop-out voltage: 30% of nominal voltage • UL recognized file No.: E37066 (US & Canada)
• Operate time: 20 ms approx. • NEMA: Exceeds NEMA Standard TS 2-2003
• Release time: 20 ms approx. • D.O.T. Approvals:
Temperature Data
• Operating ambient: -40ºC to +65ºC
• Storage ambient: -40ºC to +130ºC