MD100ERW0 pages
MD100ERWSeries
2:1 Input, 1W SIP,
Single & Dual Output
DC/DC Converters
Electrical Specications
Specications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specications subject to change without notice.
Key Features:
Input
Parameter
Conditions
Min.
5 VDC Input
4.5
12 VDC Input
9.0
24 VDC Input 18.0
48 VDC Input 36.0
5 VDC Input
3.5
12 VDC Input
4.5
24 VDC Input 11.0
48 VDC Input 24.0
Capacitor Filter
• 2:1 Input Voltage Range
Input Voltage Range
• Short Circuit Protected
• 1,500 VDC Isolation
• 29 Standard Models
• Miniature SIP Case
• -40°C to +85°C Operation
• Industry Standard Pin-Out
• Low Cost
Input Start Voltage
Input Filter
Typ.
5.0
12.0
24.0
48.0
4.0
8.0
16.0
33.0
Max.
9.0
18.0
36.0
75.0
4.5
9.0
18.0
36.0
Units
Typ.
±1.0
±0.5
±0.3
±0.4
30
55
0.5
25% Load Step Change
±2.5
±0.02
Continuous (Autorecovery)
Max.
±3.0
±1.0
±0.5
±0.75
50
75
2.0
±5.0
±0.03
Units
%
%
%
%
mV P - P
mV P - P
mSec
%
%/°C
Conditions
• 1W Output Power
Max.
Units
VDC
M
pF
kHz
VDC
VDC
Output
Parameter
Output Voltage Accuracy, See Note 1
Output Voltage Balance, See Note 2
Line Regulation
Load Regulation
Ripple (20 MHz)
Noise (20 MHz)
Transient Recovery Time, See Note 4
Transient Response Deviation
Temperature Coefcient
Output Short Circuit
Conditions
IOUT = 5% to 100%
Dual Outputs, Balanced Loads
VIN = Min to Max
IOUT = 5% to 100%
See Note 3
See Note 3
Min.
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
60 Seconds
500 VDC
100 kHz/0.1V
Min.
1,500
1,000
120
200
Standard
See Note 5
EN 55022
See Note 5
EN 55022
EN 61000-4-2
EN 61000-4-3
See Note 6
EN 61000-4-4
See Note 6
EN 61000-4-4
See Note 7
EN 61000-4-5
EN 61000-4-6
EN 61000-4-29
EFT
Surge
CS
Voltage Dips
Typ.
Level
Class B
Class B
Criteria B; ±4 kV Contact
Criteria A; 10V/m
Criteria B; ±2 kV
Criteria B; ±4 kV
Criteria B; ±2 kV
Criteria A; 3 Vrms
Criteria B; 0% - 70%
Environmental
MicroPower Direct
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Parameter
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
Case Size
Case Material
Weight
Conditions
Min.
Typ.
-40
+25
-55
Free Air Convection
RH, Non-condensing
Ambient
Max.
+85
+125
Units
°C
°C
95
%
0.866 x 0.374 x 0.472 Inches (22.00 x 9.50 x 12.00 mm)
Non-Conductive Black Plastic (UL94-V0)
0.17 Oz (4.9g)
Reliability Specications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.0
Typ.
Max.
Units
MHours
Min.
-0.7
-0.7
-0.7
-0.7
Typ.
Max.
12.0
25.0
50.0
100.0
300
Units
Absolute Maximum Ratings
Parameter
Conditions
Input Voltage Surge (1 Sec)
Lead Temperature
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case for 10 Sec
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C