ME05S series0 pages
ME05S Series
Low Cost, 0.5W
Ultra-Miniature SIP
DC/DC Converters
Electrical Specications
Specications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specications subject to change without notice.
Key Features:
• 0.5W Output Power
Input
Parameter
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
• Ultra-Miniature SIP Case
• 35 Standard Models
Input Voltage Range
• 1,000 VDC Isolation
• >1.1 MHour MTBF
Input Reected Ripple Current
Input Filter
• -40°C to +85°C Operation
Min.
2.97
4.50
10.80
21.60
43.20
Typ.
3.3
5.0
12.0
24.0
48.0
20
Max.
3.63
5.50
13.20
26.40
52.80
Units
VDC
Output
Parameter
Output Voltage Accuracy
Line Regulation
Load Regulation, See Note 1
Ripple & Noise (20 MHz)
Temperature Coefcient
Output Short Circuit
mA P - P
Internal Capacitor
Conditions
Min.
Typ.
±3.0
For VIN Change of 1%
±1.2
See Model Selection Guide
100
±0.02
Momentary (0.5 Sec.)
Max.
Units
%
%
mV P - P
%/°C
General
Parameter
Isolation Voltage
Isolation Resistance
Isolation Capacitance
Switching Frequency
EMI Characteristics, See Note 3
Parameter
Radiated Emissions
Conducted Emissions
ESD
RS
EFT
Surge
CS
PFMF
Conditions
60 Seconds
500 VDC
100 kHz, 1V
Conditions
Min.
1,000
1,000
Typ.
60
80
Min.
EN 55022
EN 55022
EN 61000-4-2
EN 61000-4-3
EN 61000-4-4
EN 61000-4-5
EN 61000-4-6
EN 61000-4-8
Max.
Typ.
Min.
-40
Typ.
Units
VDC
M
pF
kHz
Max.
Units
Class B
Class B
Criteria A; ±8 kV Air/±6 kV Contact
Criteria A; 10V/m
Criteria A; ±2 kV
Criteria A; ±0.5 kV
Criteria A; 10 Vrms
Criteria A; 1A/m
Environmental
Parameter
Operating Temperature Range
Operating Temperature Range
Storage Temperature Range
Cooling
Humidity
Physical
292 Page Street
Suite D
Stoughton, MA 02072
USA
T: (781) 344-8226
F: (781) 344-8481
E: sales@micropowerdirect.com
W: www.micropowerdirect.com
Ambient
Case
Case Material
Weight
Max.
+85
+100
+125
Units
°C
°C
°C
95
-40
Free Air Convection
RH, Non-condensing
48 VIN Models
All Other Models
Case Size
MicroPower Direct
Conditions
%
0.46 x 0.29 x 0.40 Inches (11.68 x 7.5 x 10.2 mm)
0.46 x 0.24 x 0.40 Inches (11.68 x 6.0 x 10.2 mm)
Non-Conductive Black Plastic (UL-94V0)
0.05 Oz (1.5g)
Reliability Specications
Parameter
MTBF
Conditions
MIL HDBK 217F, 25°C, Gnd Benign
Min.
1.121
Typ.
Max.
Units
MHours
Conditions
3.3 VDC Input
5 VDC Input
12 VDC Input
24 VDC Input
48 VDC Input
1.5 mm From Case For 10 Sec
Min.
-0.0
-0.0
-0.0
-0.0
-0.0
Typ.
Max.
6.0
7.0
15.0
28.0
54.0
260
Units
Absolute Maximum Ratings
Parameter
Input Voltage Surge (1 Sec)
Lead Temperature
Caution: Exceeding Absolute Maximum Ratings may damage the module. These are not continuous operating ratings.
www.micropowerdirect.com
VDC
°C
"