MPU-800U Series0 pages
APx-BT_datasheet.indd table.main {} tr.row {} td.cell {} div.block {} div.paragraph {} .font0 { font:16.00pt "Arial", sans-serif; } .font1 { font:24.00pt "Arial", sans-serif; } .font2 { font:5.00pt "Lucida Sans Unicode", sans-serif; } .font3 { font:7.00pt "Lucida Sans Unicode", sans-serif; } .font4 { font:8.00pt "Lucida Sans Unicode", sans-serif; } .font5 { font:9.00pt "Lucida Sans Unicode", sans-serif; } .font6 { font:10.00pt "Lucida Sans Unicode", sans-serif; } .font7 { font:12.00pt "Lucida Sans Unicode", sans-serif; } .font8 { font:24.00pt "Lucida Sans Unicode", sans-serif; } .font9 { font:46.00pt "Lucida Sans Unicode", sans-serif; } .font10 { font:15.00pt "Trebuchet MS", sans-serif; } MPU-800U Sries Single Output 800W Power Factor Corrected AC/DC Power Supplies Key Features: Compact 800W Supply 镕 PFC to EN 61000-3-2 "D" EN 60950 Approved (UL) Օ CE Certifie! FCC Class B Emissions 镕 Universal AC Input Current Share Option Electrical Spթcifications ^ Spcifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Spcifications subject to change without notice. Input Parameter Conditions Min. Typ. Max. Units Input Voltage Range Universal 90 264 VAC Input Frequency 47 63 Hz Input Current, Full Load 90 VAC 8.0 A Inrush Current, Cold Start 110 VAC 35 A 220 VAC 70 Leakage Current 240 VAC 3.5 mA Power Factor Correction Meets EN61000-3-2 Class D Input Protection T12A/250V Fuse Input Undervoltage Protection Under 80 VAC ±5 VAC Unit Shuts Down; Unit Recovers Over 86 VAC Output Parameter Conditions Min. Typ. Max. Units Output Voltage Adjustment By Trim Pot ±5.0 % Output Regulation, See Note 1 ±1.0 % Hold Time 120 VAC, 80% Load 20 mSec Ripple & Noise (20 MHz), See Note 2 See Model Selection Guide Overload Protection Foldback Circuit, Autorecovery 110 140 % Over Voltage Protection >130% of Rated Output Voltage. Recycle AC Input. Over Temperature Protection Autorecovery +85 °C Temperature Coefficient ±0.04 %/°C Transient Recovery Time, See Note 4 50% Load Change 2.5 mS Transient Response Deviation 5.0 % Overshoot/Undershoot At Turn On/Off ±5.0 % Turn On Delay 230 VAC 2.0 S Output Short Circuit Continuous With Autorecovery General Parameter Conditions Min. Typ. Max. Units Input - Output 3,000 Isolation Voltage, See Note 5 Input - FG (Frame Ground) 1,500 VAC Primary - Core 1,500 Switching Frequency Fixed 24 kHz Interface Signals LED Power Supply On Bi-color LED Is Green For Power On; Orange When Protection Enabled Current Monitor A 0.5 to 3.0V Output That Represents 0% to 100% Output Current Current Share Optional For Sharing Up To Four Units. Contact The Factory For Details Remote Sense Compensates For Up To A 0.5V Line Drop Power Good Signal Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. Remote On/Off A TTL low signal inhibits the output. Hiccup mode. Environmental Parameter Conditions Min. Typ. Max. Units Operating Temperature Range Ambient 0 +25 +70 °C Output Derating 2.5%/ °C from +50 °C to + 70 °C Storage Temperature Range -20 +85 °C Cooling See Model Selection Guide Operating Humidity RH, Non-condensing 90 % Reliability Specifications Parameter Conditions Min. Typ. Max. Units MTBF MIL HDBK 217F, 30°C, Gnd Benign 150 kHours Safety Standards UL 60950, EN 60950 EEMI Compliance Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EMS Immunity Compliance EN6100-4-2,3,4,5,6,8,11; EN55024; CE Marked (LVD) RoHS MicroPower Direct 292 Page Street Suite D Stoughton, MA 02072 USA T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Vibration Sinusoidal 5~50 Hz, Acceleration ±7.35 m/s2 on X, Y & Z Axis www.micropowerdirect.com
"