PPS40LB Series0 pages
AC-DC Converters
www.powersolve.co.uk
PPS40LB Series
40 Watts
Single, Dual, Triple & Quad Outputs
Features
• Universal AC input
• Built-in EMI filter
• Low cost
• Optional constant current change (for single output)
Electrical Specification
INPUT
Input range
Frequency
Inrush current
Efficiency
EMI filter
Line regulation
OUTPUT
Maximum power
Peak power
Hold-up time
Overload protection
Overvoltage protection
Ripple/Noise
Output adjust
ENVIRONMENTAL
Operating temperature
Humidity
Vibration
Storage temperature
Temperature coefficient
MTBF demonstrated
EMI & EMC
Safety approval
90~264 VAC, universal
47~63Hz
30A typical, Cold start @ 25°C, 115 VAC
65% ~80% typical at full load
FCC Class B conducted, CISPR 22 Class B conducted, EN55022 class B conducted
± 0.5% typical
40W convection
52 watts
10ms typical at full load and 115 VAC nominal line
Short circuit protection
Main output 20% to 40% above nominal output
± 1% Max. @ full load (Optional ±0.5% per inquiry)
± 10% output 1
0 to 5 ambient; derate each output at 2.5% per degree from 50°C to 70°C
Operating; non-condensing, 5% to 95%
10~55 Hz at 1G 3 minutes period, 30 minutes along X, Y and Z axis
-40 to 85
± 0.05% per degree C
>100,000 hours at full load and 25°C ambient conditions
FCC part 15, Class B
CISPR 22 / EN55022, Class B
VCCI, Class 2
CE, EN 61000-3-2 (Class A) and –3; EN 61000-4-2, -3, -4, -5, -6 and -11
UL, cUL, TUV EN60950
Power Derating Curve
65W
40W
Output
Power 25W
(Watts) 10W
Natural
Convection
Cooling
20 W
0W
0
10
20
30
40
50 60
70
Ambient Temperature (°C)
Powersolve Electronics Ltd. Units 8A, Arnhem Road, Newbury, RG14 5RU. England
Tel:01635 521858 Fax: 01635 523771 Email: sales@powersolve.co.uk