ECU-04 / ECU-050 pages
ECU-04 / ECU-05
Universal Add-on Auto-Start Control For All Manual
Key Start Generator Sets
Features
Microprocessor Automatically Mimics The Manual Start Procedure
Simple Installation, Without Changing Original Wiring
Easy to Set Up, low-cost, Small Size, Low Power Consumption
For Use In Gasoline And Diesel Generators
Three Attempts Multi-Start Function
Circuits Are Protected With 94-V0 Epoxy
Two Adjustable Time Delay Potentiometers
Specifications
12 VDC (ECU-XX-12V)
30 Amp @ 12/24 VDC
Start Signal Output
30 Amp @ 12/24 VDC
100~240 VAC
Pre-Heat or Carburetor Signal Output
30 Amp @ 12/24 VDC
50~60 Hz
Alternator Input Range
Ignition & Accessories Signal Output
24 VDC (ECU-XX-24V)
DC Supply
Auxiliary Signal Output
20 Amp @ 12/24 VDC
Time Delay Setting And Alarm Indicators
L1
Remote Start Activated Indicator LED
VR1
Engine Pre-Heat Time Adjustment (1~25 Seconds)
L2
Generator Running Indicator LED
VR2
Starter Cranking Time Adjustment (1~25 Seconds)
L3
Start Fail Indicator LED
SW
Function Selectable Switch
Environment
-20~80 ℃
Operating Temperature
Mechanical Specifications
Relative Humidity
(Unit : mm)
150.0
31.0
138.0
11 10 9
8
7
6
Maximum 95%
15.0
5
4
3
2
ECU-04
SW On
For Use on Diesel Engine with Pre-Heat
SW Off
1
For Use on Gasoline Engine with Carburetor
ECU-05
SW On
For Use Terminal NO.3 with Pre-Heat
88.0
100.0
Function
SW Off
For Use Terminal NO.3 with Energize to Stop
Function
Physical Specification
5.0
Dimensions
VR1 VR2
L1 L2 L3 SW
150.0 (L) x 100.0 (W) x 31.0 (H) mm
Weight
ECU-04
368 g ±2%
ECU-05
373 g ±2%
TEL: +886-7-8121771
FAX: +886-7-8121775
Head Office: No.3, Lane 201, Chien Fu St., Chyan Jenn Dist., Kaohsiung, TAIWAN
Please link to http://www.kutai.com.tw for detailed manual.