Catalogue 2016 - nSens RH/T probe with Modbus adapter0 pages
nSens probe for integration in BUS networks
nSens for BUS networks
This adapter system allows a protocol transformation and hence nSens probes can be easily
integrated in new and existing bus networks (Modbus). The operator benefits from a simple and
fast integration in combination with the high measurement accuracy and linearity of the nSens
sensors. This solution offers a cost efficient alternative to the use of transmitter systems with
analogue output signals.
Applications:
Clean rooms
Isolators
Operating theaters
Labs, calibration rooms
Your advantages:
Fully integration of measurement points in the
network
Reliable digital signal transmission
Simple to install thank to small dimensions
Probe can be replaced fast and easy thanks to
the with connection system
High measurement accuracy and linearity
Cost efficient and flexible solution
Industries:
Pharmaceutical
Life Science
Semiconductor
Hospitals
Pharmacies etc.
Simple and fast to verify and calibrate the
measuring probes
nSens network solutions
for direct integration in a Modbus network
nSens-HT-ENS and nSens-T-NBS probe
Dimensions:
Digital nSens-HT humidity & temperature probe
with resistive-electrolytic humidity- and NTC temp.
sensor. With nCap-PS protection filter cap.
Communication:
Digital nSens-T temperature probe with high quality
NTC temperature sensing element and nCap-E
protection cap.
260 1171
260 1172
nSens-HT-ENS
nSens-T-NBS
The calibration points are saved directly on the
probe. The verification and calibration is done by the
separately available nSoft-CAL calibration software.
The plug-in probe can be replaced very easily.
Fact. calibration:
(nSens-T)
Fact. calibration:
(nSens-HT)
Verification &
Calibration:
L101mm x 13mm
Detailed information
can be found in the
technical data sheet.
digital by Bus-system
at 2 temperature
points incl. certificate
at 5 humidity
points incl. certificate
with nSoft-CAL
software
Probes delivered in a separate package.
nLink-Modbus adapter for nSens (HT/T)
20 x 60 mm
Signal conversion adapter from nSens probes to
Modbus.
Weight:
approx. 30 g
Connector:
5 pole screwed
for Modbus and
3 pole for nSens
Modbus-cable - length 2m
Cable length:
2m
For connection of a nLink-Modbus adapater to a Modbus
network
260 1095 nLink-Modbus
Dimensions:
Weight:
approx. 100 g
Connector:
M12 / 4
respectively
open cable head
Remark: each nSens probe requires 1 nLink-Modbus for
connection.
adapter
Adapter-side with M12/4 connector
Network-side with open cable head
260 1135 Bus cable
length 2m
Doc. 005221.00
General catalogue AIR 2016
page 17 / 37
"