HY-OPTIMA 2700 Explosion Proof In-line Hydrogen Process Analyzer0 pages
2scan
nnnnTechnical Data and Specifications
nnnnHydrogen is the future, we can sense it!
nnnnHY-OPTIMA™ 2700 Explosion Proof In-line Hydrogen Process Analyzer
nnnnDescription
nnnnH2scan's HY-OPTIMA"™~2700 real time hydrogen-specific process analyzers are designed for ease of use, interface
nnnnflexibility and true process control. The HY-OPTIMA 2700 uses a solid-state sensor that is configured to operate in
nnnnprocess gas streams. The HY-OPTIMA™ 2700 is ideal for hydrogen production and petrochemical applications
nnnnwhere real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management.
nnnnPerformance
nnnnHydrogen Sensitivity Range:
nnnn0.5% to 100% hydrogen by volume at 1 ATM
nnnnResponse Time: T90 < 30 sec
nnnnIngress Protection: IP64 capable
nnnnRecommended Verification Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnAccuracy(*):
nnnn± 0.3% absolute for 0.5 to 10% H2
nnnn± 1.0% absolute for 10 to 100% H2
nnnnDrift/week:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnRepeatability:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnLinearity:
nnnn± 0.2% absolute for 0.5-10% H2
nnnn± 0.4% absolute for 10-100% H2
nnnnOperating Conditions
nnnnInterface Options
nnnnInput Voltage Range: 90 VAC to 240 VAC
nnnnInput Power: 15W
nnnnAnalog Outputs:
nnnnOutput Currents
nnnn• 4 mA to 20 mA
nnnn• 0 mA to 20 mA
nnnn• User-specific mA range
nnnnSerial Communication Options: RS232 or RS422
nnnnRelay Contacts: Two programmable relays and
nnnnone fault relay with both normally open (N.O.)
nnnnand normally closed (N.O) contacts:
nnnn• 5A/240VAC
nnnn• 5A/ 30 VDC
nnnnVL
nnnnCertifications:
nnnnUL 1203
nnnnUL508
nnnnUSC - Class I, Division 1, Groups B, C, and D
nnnnHazardous (Classified)
nnnnOperating Humidity: 0% to 95% RH (non-condensing)
nnnnFlow Rate: 0.1 slpm to 50 slpm
nnnnPressure: 0 to 7 bar gauge, 0 to 100 psi gauge
nnnnProcess Gas Temperature Range: -20°C to 110°C
nnnnOperating Temperature Range: -20°C to 55°C
nnnnStorage Temperature Range: -30°C to 80°C
nnnnCalibration Background Gas: Nitrogen
nnnnAdapter Fittings
nnnn3A" Union Tee Compression
nnnnDimensions
nnnnWidth: 13.8 cm (5.4 in)
nnnnLength: 19.2 cm (7.5)
nnnnDepth: 13.0 cm (5.7 in)
nnnno
nnnno
nnnnci
nnnnCO
nnnnO
nnnnCO
nnnnCM
nnnnc
nnnno
nnnn55
nnnnS
nnnnCD
nnnncc
nnnnco
nnnn-3>
nnnnCD
nnnn—I
nnnn* Sensor performance specifications are only valid for units configured for a maximum 65°C dry process stream and at 25 °C ambient temperature. All
nnnnfigures assume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The
nnnnaccuracy is specified for serial port output only._
nnnnHY-OPTIMA™ is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, Valencia CA., 91355
nnnnSpecifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515
nnnn90000057 R2 Email: sales(5).h2scan.com, Website: www.h2scan.com
"