HY-OPTIMA 1700AS, TECHNICAL DATA SHEET0 pages
2scan
nnnnHydrogen is the future, we can sense it! ™
nnnnTechnical Data and Specifications
nnnnHY-OPTIMA™ 1700AS Process Hydrogen Analyzing System (Refinery Std & % H2S & CO)
nnnnDescription_
nnnnH2scan's HY-OPTIMA™ Model 1700AS Process Hydrogen Analyzing System provides a complete solution for
nnnnprocess hydrogen measurement in refineries, chemical plants, air separation units and industrial gas manufacturing
nnnnplants. The system comprises H2scan's hydrogen specific analyzer in a NEMA 4X enclosure with sampling systems
nnnnand is capable of operating in a broad spectrum of process conditions.
nnnnSensor Performance
nnnnHydrogen Sensitivity Range:
nnnn0.5% to 100% hydrogen by volume at 1 ATM
nnnnResponse Time: T90 < 30 sec
nnnnIngress Protection: IP64 capable
nnnnRecommended Verification Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnAccuracy(*):
nnnn± 0.3% absolute for 0.5 to 10% H2
nnnn± 1.0% absolute for 10 to 100% H2
nnnnDrift/week:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnRepeatability:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnLinearity:
nnnn± 0.2% absolute for 0.5-10% H2
nnnn± 0.4% absolute for 10-100% H2
nnnnInterface Options
nnnnAnalog Output: 4 mA to 20 mA
nnnnSerial Communication: RS422
nnnnOperating Conditions
nnnnInlet Conditions:
nnnnInlet pressure: 30-510 PSIG*
nnnnProcess temperature: -20 - 100°C*
nnnnOperating Voltage: 15VAC/230VAC
nnnnEnclosure Classification: NEMA 4X
nnnnSample Flow Rate: .8 to 1 SLPM*
nnnnIncluded Accessories
nnnnIntrinsically Safe Power Barrier
nnnnArmored Power / Analog Cable: 4 m
nnnnSerial Interface Cable: 4 m (custom lengths optional)
nnnnOptional Accessories
nnnnSingle Channel Intrinsically Safe Analog Output
nnnnBarrier (with or without relays)
nnnnSingle Channel Intrinsically Safe RS422 Interface
nnnnBarrier Vortex Cooler
nnnnEnclosure Heater: 200 Watts, 1.74 Amps at 115 VAC
nnnnDimensions*
nnnnLength: 24"
nnnnHeight: 24"
nnnnWidth: 10"
nnnnSupport & Warranty
nnnn1 year all parts and labor
nnnnField support available upon request
nnnn* Can be customized per customer requirements.
nnnnt Higher accuracy spec is available for model
nnnn1740 under controlled process conditions.
nnnnHY-OPTIMA™ is a registered Trademark of H2scan
nnnnSpecifications subject to change without prior notice
nnnn90000046 R1
nnnn27215 Turnberry Lane, Unit A, Valencia CA., 91355
nnnnTel: 661-775-9575, Fax: 661-775-9515
nnnnEmail: sales(5).h2scan.com, Website: www.h2scan.com
"