HY-OPTIMA 1730, TECHNICAL DATA SHEET0 pages
Technical Data and Specifications
nnnn2scan
nnnnHydrogen is the future, we can sense it! ™
nnnnHY-OPTIMA™ 1730 Intrinsically Safe In-line Process Hydrogen Analyzer (ppm H2S & CO)
nnnnDescription_
nnnnH2scan's HY-OPTIMA'"" 1730 in-line, real time hydrogen-specific process analyzers are designed for ease of use,
nnnninterface flexibility and true process control. The HY-OPTIMA™ 1730 is an intrinsically safe device that
nnnnincorporates our patented solid-state sensor and is configured to operate in background gas streams having carbon
nnnnmonoxide concentrations up to 100 ppm, hydrogen sulfide stream concentrations up to 1000 ppm, up to 95%
nnnnrelative humidity and temperatures up to 100°C. The HY-OPTIMA™ 1730 is ideal for hydrogen gas production,
nnnnpetroleum refining and petrochemical applications where continuous real time measurements of hydrogen can
nnnnincrease process plant efficiencies, improve diagnostics and enhance maintenance management translating into
nnnnhigher profitability.
nnnnPerformance
nnnnHydrogen Sensitivity Range:
nnnn0.5% to 100% hydrogen at 1 ATM
nnnnResponse Time: T90 less than 30 sec
nnnnIngress Protection: IP64 capable
nnnnRecommended Verification Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnAccuracy(*):
nnnn± 0.3% absolute for 0.5 to 10% H2
nnnn±1.0% absolute for 10 to 100% H2
nnnnDrift/week:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnRepeatability:
nnnn± 0.2% absolute for 0.5 to 10% H2
nnnn± 0.4% absolute for 10 to 100% H2
nnnnLinearity:
nnnn± 0.2% absolute for 0.5-10% H2
nnnn± 0.4% absolute for 10-100% H2
nnnnOperating Conditions
nnnnOperating Humidity: 0% to 95% RH
nnnnFlow Rate: 0.1 slpm to 50 slpm
nnnnPressure: 0 to 7 bar gauge, 0 to 100 psi gauge
nnnnProcess Gas Temperature Range: -20°C to 100°C
nnnnOperating Temperature Range: -20°C to 40°C
nnnnStorage Temperature Range: -40°C to 50°C
nnnnCalibration Background Gas: Nitrogen
nnnnInterface Options
nnnnPower Barrier Input Voltage: 24 VDC nominal
nnnnPower Barrier Input Voltage Range: 20 VDC to 28 VDC
nnnnIntrinsically Safe Sensor Input Voltage: 10 VDC
nnnnSensor Input Voltage Range: 5 VDC to 28 VDC
nnnnInput Power: 10 W
nnnnAnalog Output: 4 mA to 20 mA
nnnnSerial Communication Options: RS422
nnnnCertifications
nnnn^ ^ 0359
nnnnII 1 G, Exia II H2, d+d IIBT3
nnnnII 2 G, Exib II H2, ib d IIBT3
nnnnITS07ATEX25634X
nnnnIncluded Accessories
nnnnIntrinsically Safe Power Barrier
nnnnArmored Power / Analog Cable: 4 m
nnnnCalibration Cup
nnnnOptional Accessories
nnnnSingle Channel Intrinsically Safe Analog Output
nnnnBarrier (with or without relays)
nnnnSingle Channel Intrinsically Safe RS422 Serial
nnnnInterface Barrier
nnnnSerial Interface Cable: 4 m (custom lengths
nnnnavailable)
nnnnArmored Power / Analog Cable (custom lengths
nnnnavailable)
nnnnAdapter Fittings
nnnn1/2in. MNPT thread
nnnn1/2in. FNPT thread
nnnn-8 SAE/MS thread size
nnnn... and many other industry standards
nnnnDimensions
nnnnTotal Length: 10.3 in.
nnnnLength of Enclosure: 6.8 in
nnnnLength of Tube: 2.9 in.
nnnnWidth: 3.4 in.
nnnn* Sensor performance specifications are only valid for units configured for a maximum 65°C dry process stream temperature. All figures
nnnnassume pressure compensation, operating in ambient that do not contain Oxygen and are in addition to any errors in the gasses used. The
nnnnaccuracy is specified for serial port output only.
nnnnHY-OPTIMA is a registered Trademark of H2scan
nnnnSpecifications subject to change without prior notice
nnnn90000048 R1
nnnn27215 Turnberry Lane, Unit A, Valencia CA., 91355
nnnnTel: 661-775-9575, Fax: 661-775-9515
nnnnEmail: sales(5).h2scan.com, Website: www.h2scan.com
"