HY-ALERTATM 1600 Intrinsically Safe Area Hydrogen Monitor Data Sheet0 pages
l2scai |
Hydrogen is the future, we can sense it! ™
nnnnTechnical Data and Specifications
nnnnHY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor
nnnnDescription
nnnnH2scan's HY-ALERTA™ 1600 Intrinsically Safe Area Hydrogen Monitor provides hydrogen-specific leak detection
nnnnand measurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5%
nnnnhydrogen by volume, a range representing 10% to 125% of hydrogen's low flammability limit. The monitor is designed
nnnnfor either ceiling or wall mount and has an RS422 capability that extends an intrinsically safe interface from the sensor
nnnnto the controller to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross sensitivity to
nnnnother combustible gases, thus eliminating false positive alarms and ensuring safety system reliability.
nnnnPerformance
nnnnHydrogen Sensitivity Range:
nnnn0.4% to 5% hydrogen by volume
nnnn10% to 125% hydrogen lower flammable limit
nnnnAccuracy: ± (0.03 x indication + 0.2) percent
nnnnhydrogen by volume
nnnnTypical Response Time: T90 of 60 sec maximum
nnnnIngress Protection: IP64 capable
nnnnCalibration Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnInterface Options
nnnnPower Barrier Input Voltage: 24 VDC nominal
nnnnPower Barrier Input Voltage Range: 20 VDC to 28 VDC
nnnnIntrinsically Safe Sensor Input Voltage: 10 VDC
nnnnSensor Input Voltage Range: 5 VDC to 28 VDC
nnnnInput Power: 10VV
nnnnAnalog Output: 4 mA to 20 mA
nnnnSerial Communication: RS422
nnnnCertification
nnnnOperating Conditions
nnnnOperating Humidity: 0% to 95% RH
nnnnOperating Temperature Range: -20°C to 40°C
nnnnStorage Temperature Range: -40°C to 50°C
nnnnCalibration Background Gas: Air
nnnnIncluded Accessories
nnnnIntrinsically Safe Power Barrier
nnnnArmored Power / Analog Cable: 4 m
nnnnCalibration Cup
nnnnOptional Accessories
nnnnSingle Channel Intrinsically Safe Analog Output Barrier
nnnn(with or without relays)
nnnnSingle Channel Intrinsically Safe RS422 Serial Interface
nnnnBarrier
nnnnSerial Interface Cable: 4 m (custom lengths available)
nnnnArmored Power/ Analog Cable (custom lengths
nnnnavailable)
nnnnDimensions
nnnnTotal Length: 8.1 in.
nnnnTotal Width: 4.4 in.
nnnnDepth: 1.6 in.
nnnnFigure 1 shows the hazardous area designations for this apparatus. Note that the
nnnnsensor probe tip is rated for Category 1 (Zone 0) and the electronics assembly is
nnnnrated for Category 2 (Zone 1).
nnnnC€o359^2>
nnnnII 1 G, Ex ia II H2, d+d IIBT3
nnnnII 2 G, Ex ib II H2, ib d MB T3
nnnnITS07ATEX25634X
nnnnHY-ALERTA is a registered Trademark of H2scan
nnnnSpecifications subject to change without prior notice
nnnn90000009 R2
nnnn27215 Turnberry Lane, Unit A, Castaic CA., 91384
nnnnTel: 661-775-9575, Fax: 661-775-9515
nnnnEmail: sales@h2scan.com, Website: www.h2scan.com
"