V100E-IS0 pages
Model: V100EIS
VALVE ACCESSORIES & CONTROLS
INTRINSICALLY SAFE POSITIONER
A line of pneumatic valve positioners incorporating over
sixty years of design, manufacturing and marketing
expertise, creating one of the most durable, reliable
instruments on the market.
This positioner can be ordered with either European or US
certification on the I/P converter thus allowing it to be used
in hazardous locations. Certificates from CSA, FM and
ATEX are available.
Accessories in the way of gauges, feedback modules or
a raised indicator can be added in a matter of minutes.
Maximum modularity equals maximum flexibility and with a
simple design and quality components, the performance
is a maximum as well.
Input Signal
4-20 mA ( Ri<250 ohms )
Thread sizes
Air connections
Supply Pressure
0.15 - 1MPa (21.8 - 145 PSI)
Electrical entry
Gauge ports
Linearity Error
<1.0% FS
Ingress Protection
IP66 (NEMA 4X)
Hysteresis
<0.6% FS
Surface Finish
Powder Polyester
Repeatability
<0.5% FS
Weight
1.7Kg (3.8lbs)
Pressure Gain
@ 600KPa (87PSI) according to ISA S75.13
750 Pout/Pin
49% Pout/Pin
Air Capacity
@ 200KPa (29PSI)
@ 600KPa (87PSI)
@ 1MPA (145PSI)
Bleed Rate
@ 200KPa (29PSI)
@ 600KPa (87PSI)
@ 1MPA (145PSI)
1/4"G
Optional 1/4"NPT
M20
Optional 1/2"NPT or PG13.5
1/8"G
Optional 1/8"NPT
270SLM
800SLM
1350SLM
9.5SCFM
28.3SCFM
47.1SCFM
Options
Various Spindles for different actuators
Various cams
Gauges
Indicators
Pilot Valves
Temperature Range
Depending on electrical rating
-40 to +85 Celsius (-40 to +185 Fahrenheit)
Certification
FM
CL I-II-III / DIV I / Grp A B C D E F G
CSA
CL 1 DIV 1 Grp ABCD; CL 11 DIV 1 Grp EFG; CL 111
CL 1 DIV 2 Grp ABCD; CLI 1 DIV 2 Grp EFG
ATEX
II 1G Eex ia IIC T4-6
Benefits
Simple calibration. With the non-interactive zero and span
adjustment and the external zero adjustment, calibration
is simple and time saving.
Flexibility. One housing for pneumatic or electro-pneumatic.
The I/P can be installed or removed at any time. Multiple
mounting capability. Standard indicator allows for air to
open or air to close operation. Flat or raised indicator
Benefits
Maintenance friendly. The pilot valve assembly can be
cleaned by removing one screw and can only be installed
one way - the correct way. The gauge block is standard.
I/P test point positioner loop testing.
Durable. Cast aluminium, polyester coated housing.
Stainless steel retained fasteners. Double locked stainless
steel cam. Quality internal parts. Unique electrical compart-
available. F05 standard housing with changeable drives.
ment fitted with an o-ring is pressure sealed by the cover.
Rev-04 August 2009
5.7SLM
17SLM
28.3SLM
0.2SCFM
0.6SCFM
1.0SCFM