HY-ALERTA 600 TECHNICAL DATA SHEET0 pages
2scan
nnnnHydrogen is the future, we can sense it! ™
nnnnTechnical Data and Specifications
nnnnHY-ALERTA™ 600 Fixed Area Hydrogen Saftey Monitor
nnnnDescription_
nnnnH2scan's HY-ALERTA™ 600 Fixed Area Hydrogen Monitor will provide hydrogen-specific leak detection and
nnnnmeasurement for hydrogen concentrations as low as 4000 ppm and can be scaled to any concentration up to 5%
nnnnhydrogen by volume, a range representing 10% to 125% of hydrogen's low flammability limit. The monitor is
nnnndesigned for either ceiling or wall mount and has an RS422 capability that extends the interface from the sensor to
nnnnthe controller to several hundred feet. H2scan's hydrogen-specific sensor technology has no cross sensitivity to any
nnnnother combustible gases, thus eliminating false positive alarms and increasing system reliability.
nnnnPerformance
nnnnOperating Conditions
nnnnHydrogen Sensitivity Range:
nnnn0.4% to 5.0% hydrogen by volume,
nnnn10% to 125% hydrogen lower flammable limit
nnnnAccuracy: ± (0.03 x indication + 0.2) percent
nnnnhydrogen by volume
nnnnTypical Response Time: T90 of 60 sec maximum
nnnnIngress Protection: IP64 capable
nnnnCalibration Interval: 90 days
nnnnProduct Life Expectancy: 10 years
nnnnInterface Options
nnnnInput Voltage Range: 8 VDC to 13 VDC
nnnnInput Current: 1.0 A
nnnnAnalog Outputs:
nnnnOutput Voltages - OR - Output Currents
nnnn• 0 VDC to 5 VDC • 4 mA to 20 mA
nnnn• 1 VDC to 5 VDC • 0 mA to 20 mA
nnnn• 0 VDC to 4 VDC • User-specific mA range
nnnn• 0.5 VDC to 4.5 VDC
nnnn• User-specific VDC range
nnnnSerial Communication Options: RS232 or RS422
nnnnRelay Contacts: Two programmable 60 VDC /1 A
nnnnSPDT relays with both normally open (N.O.) and
nnnnnormally closed (N.O) contacts.
nnnnCertifications:
nnnn.<£>
nnnnUS LISTED
nnnnOperating Temperature Range: -20°C to 40°C
nnnnStorage Temperature Range: -40°C to 50°C
nnnnOperating Humidity: 0% to 95% RH
nnnnCalibration Background Gas: Air
nnnnDimensions
nnnnTotal Length: 7.2 in.
nnnnMounting Bracket Length: 5.6 in.
nnnnTotal Width: 4.4 in.
nnnnMounting Bracket Width: 4.0 in.
nnnnDepth: 1.6 in.
nnnnHY-ALERTA™ is a registered Trademark of H2scan 27215 Turnberry Lane, Unit A, CA., 913
nnnnSpecifications subject to change without prior notice Tel: 661-775-9575, Fax: 661-775-9515
nnnn90000006 R4 Email: sales@h2scan.com. Website: www.h2scan.com
"