SLR2.1000 pages
Baby with redundancy
CB
scheme
SLR2.5
IEC60950
Data sheet
UL508 LISTED
IND. CONT. EQ.
18 WM, 60°C
•
•
•
•
•
•
Input: AC 230V/115V, DC 160-375V
Output: 24V/2.5A
High overload current, no switch-off
Quasi-Wide-Range Input
N+1 redundancy, RDY relay contact
NEC Class 2 Power Supply
Input
Input voltage
The
Redundant
Variant
UL60950 E137006
CUL/CSA-C22.2
No 950-M90
EMC and
Low Volt.
Directive
Output
AC100-120/220-240 V (switchable), 47-63 Hz
(85-132 VAC / 176-264 VAC, 160-375 VDC, see
also „Output: Continuous Loading“)
Quasi-Wide-Range Input: With the switch in the 230V position the power-supply unit operates at low and moderate loads at any input voltage
between 95 and 264 V AC (see ’Output’ at the right side).
Note: At DC input, always leave the switch in the 230V position
Input current
< 1.3 A (switch in 115V position)
< 0.7 A (switch in 230V position)
DC input current
at open output
typ. 5.3 mA at 110 VDC, 3.9 mA at 300 VDC
(preserves battery sources)
Inrush current
typ. < 25 A at 264 V AC and cold start
To be fused with a 10A, B-type 'circuit-breaker' switch based on the
usual thermomagn. overload sensing principle (used anyway to fuse
the input lines). In addition, the unit contains an internal fuse (not accessible)
Transient
handling
Transient resistance acc. to VDE 0160 / W2
(750 V / 1.3 ms), for all load conditions.
Hold up time
> 20 ms at 196 VAC, 24 V / 2.5 A
(see diagram overleaf)
Efficiency, Reliability etc.*
Rated output voltage
24 V DC
For balanced current sharing during parallel operation:
Soft characteristic (25.2 V DC ±2% at no-load, 24 V DC ±0.5% at nominal load, almost linear characteristic curve)
Output noise
suppression
Radiated EMI values below EN 61000-6-3, even
when using long, unscreened output cables.
Ambient temperature
range Tamb
Operation: -10°C...+70°C (>60°C: Derating)
Storage: -25°C...+85°C
Switch
Continuous loading
(at Tamb = -10°C...+60°C,
230V
convection cooling),
see also diagram overleaf. For start at
Tamb<0°C and low input
voltage, please contact
PULS.
* For start with DC input
> 95 V DC needed
AC/DCin
176-264 V
Iout
ACin
2,5 A
95-176 V
ACin
1,5 A
160-375 V
DCin
2,5 A
120-160 V
DCin
2,0 A
80*-120 V
DCin
1,5 A
Output protected against short circuit, open circuit and overload
(at Tamb=+60°C...+70°C)
Derating
typ. 1.5 W/K
Voltage regulation
better than 2% Vout overall
Ripple / Noise
< 30 mVPP, (20 MHz bandw., 50 Ω measurem.)
Efficiency
typ. 86.5 %
(230 VAC, 24 V / 2.5 A)
Overvolt. protection
typ. 32 V
Losses
typ. 9.4 W
(230 VAC, 24 V / 2.5 A)
Parallel operation
MTBF
700,000 h acc. to Siemensnorm SN 29500
(24 V/2.5 A, 230 VAC, Tamb = +40 °C)
yes; current sharing via soft characteristic
(see diagram)
Power back immunity
26 V
Front panel indicator
Green LED
RDY relay contact
• Type
• closes
• opens
• Electrical isolation
• Contact rating
normally open contact
when output voltage > 22.1V ±4%
when output voltage < 19.8V ±4%
500V DC to output voltage
1A at 28V DC
Life cycle (electrolytics) The unit exclusively uses longlife electrolytics,
specified for +105°C (cf. ’The SilverLine’, p.2).
Construction / Mechanics*
Housing dimensions and Weight
• WxHxD
• Free space for
ventilation
• Weight
49 mm x 124 mm x 102 mm (+ DIN rail)
above/below 25 mm recommended
right 10 mm recommended (front view)
470 g
*
*For further information see data sheets „The SilverLine“, „SilverLine Family
Branches“ and mechanics data sheet
Design advantages:
• Input and output pluggable by means of Combicon® plug connector.
• Ensure strain relief of the plug connectors
when installing the unit.
• Input and output are strictly apart from each other and so cannot be
mixed up (input below, output above).
Order information
Order number
Description
SLR2.100
SL2.100
SLZ01
N+1 redundancy*
Basic version without redundancy*
Screw mounting set, two needed per unit
slr2e100 / 040121
1/2
"